User Manual
F712T0002, valid for F-712.MA1 and F-712.MA2
Mma, BRo, 12/6/2019
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany
Page 15 / 45
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email
F-712.MA2 Coordinate Systems and Axis Identifiers
The coordinate systems shown below are active by default for F-712.MA2 systems.
Figure 5: F-712.MA2: Orientation of the coordinate systems (right-hand rule)
Axis identifier in
the controller
Axis name* in the
controller
Connected to E-712K236**
Notes
1
SPX
Module 1: E-711.SA6, Ch 1 to 3
Module 2: E-711.AL41
Piezo-driven
axes of sender
2
SPY
3
SPZ
4
RPX
Module 1: E-711.SA6, Ch 4 to 6
Module 3: E-711.AL41
Piezo-driven
axes of receiver
5
RPY
6
RPZ
7
SMX
Module 4: E-711.C82, Ch 1
Spindle-driven
axes of sender
8
SMY
Module 4: E-711.C82, Ch 2
9
SMZ
Module 5: E-711.C82, Ch 1
10
RMX
Module 5: E-711.C82, Ch 2
Spindle-driven
axes of receiver
11
RMY
Module 6: E-711.C82, Ch 1
12
RMZ
Module 6: E-711.C82, Ch 2
*The axis name can be changed via the
Axis Name
parameter of the E-712K236 controller.
**The modules of the E-712K236 controller are labeled with their module number.