0x30 Maximum Travel In Negative Direction (Phys. Unit)
Used in: Settings for the soft limits (39)
Description:
Soft limit in a negative direction, in relation to the zero position.
The negative travel range limit cannot be used for reference moves
if this value is greater than the position value for the negative travel
range limit (that results from the difference between parameters
Data type
FLOAT
Command level
0
Item type
Axis
Source of data
Positioner database
Possible values
The value can be negative.
0x31 Invert Reference?
Used in: Reference Point Switch Detection (37), Using Digital Input as Reference Signal (80)
Description:
Should the reference signal be inverted?
Inverts the signal of the reference point switch or a digital input that
is used instead of the reference point switch.
Data type
INT
Command level
0
Item type
Axis
Source of data
Positioner database
Possible values
0 Reference signal not inverted
1 Reference signal inverted
10 PARAMETER REFERENCE
PZ285EN
‒
1/30/2019
184
M O T I O N | P O S I T I O N I N G