SAI Set Current Axis Identifiers
Description:
Sets the axis identifier for the specified axis.
Long description
The new axis identifier is stored in the nonvolatile memory of the
electronics.
Use
to query the valid characters for the axis identifier.
Format:
SAI{␣<AxisID>␣<NewIdentifier>}
Arguments:
<AxisID>
Axis ID
<NewIdentifier>
New axis ID
SAI? Get List Of Current Axis Identifiers
Description:
Queries the axis identifiers.
Long description
ALL ensures that the response also includes axes that are deactiva-
ted for electronics that permit axes to be deactivated.
Format:
SAI?[␣ALL]
Arguments:
[
␣
ALL]
Ensures that electronics that allow axes to be de-
activated (parameter
= "NOSTAGE")
also allow deactivated axes to be queried.
Response:
{<AxisID>
␊
}
<AxisID>
Axis ID
SEP Set Non-Volatile Memory Parameters
Used in: Parameter Commands (104)
Description:
Sets a parameter in the nonvolatile memory to a specific value.
Long description
Up to four parameters can be set per command.
Wrong values can lead to faulty operation or damage to the hard-
ware.
Format:
SEP␣<Pswd>{␣<ItemID>␣<PamID>␣<PamValue>}
Arguments:
<Pswd>
Password for writing to the nonvolatile memory
<ItemID>
Element of the electronics
<PamID>
Parameter ID
<PamValue>
Parameter value
Troubleshooting:
Impermissible element identifier
Wrong parameter ID
Wrong password
9 COMMAND REFERENCE