RPA Reset Volatile Memory Parameters
Used in: Parameter Commands (104)
Description:
Resets the specified parameter.
Long description
The parameter value in the volatile memory is overwritten by the
value in the nonvolatile memory.
RPA resets the parameter for the setting of hardware-specific pa-
rameters. Wrong values can lead to faulty operation or damage to
the hardware.
Format:
RPA[{␣<ItemID>␣<PamID>}]
Arguments:
<ItemID>
Element of the electronics
For example, axis identifier
Parameter <PamID> is reset for this element.
<PamID>
Parameter ID
Troubleshooting:
Impermissible element identifier
Wrong parameter ID
RTR Set Record Table Rate
Used in: Setting the record table rate (74)
Description:
Sets the record table rate of the data recorder.
Long description
The recording rate multiplied by the cycle time of the electronics re-
sults in the recording interval of the data recorder. Settings greater
than 1 allow recording over longer periods of time.
Format:
RTR <RecordTableRate>
Arguments:
<RecordTableRate> Data recording rate of the data recorder in num-
ber of cycles (UINT >0)
RTR? Get Record Table Rate
Used in: Setting the record table rate (74)
Description:
Queries the current recording rate of the date recorder.
Long description
The recording rate multiplied by the cycle time of the electronics re-
sults in the recording interval of the data recorder. Settings greater
than 1 allow recording over longer periods of time.
Format:
RTR?
Response:
<RecordTableRate>
␊
<RecordTableRate> Data recording rate of the data recorder in num-
ber of cycles (UINT >0)