CTO Set Configuration Of Trigger Output
Used in: Digital Output Signals (76), Setting Signal Polarity (79), Setting Up "Motion Error" Trigger Mode (78),
Setting Up "On Target" Trigger Mode (78), Setting Up "Position Distance" Trigger Mode (77), Setting Up "Position
+Offset" Trigger Mode (78), Setting Up "Single Position" Trigger Mode (79)
Description:
Configures the trigger output conditions for the specified digital out-
put line.
Long description
Available CTO parameters:
<CTO -
Pam>
Parameters
Possible val-
ues for <Val-
ue>
Description
1
TriggerStep
0
Distance
2
Axis
(Axis identi-
fier)
Selects the axis that the trigger
output is configured for.
3
TriggerMode 0
PositionDistance
A trigger pulse is output each
time the axis has traveled the
distance set with TriggerStep
(<CTOPam> 1).
2
OnTarget
The on-target status of the se-
lected axis is transferred to the
selected digital output line.
5
MotionError
The selected digital output line
becomes active when a mo-
tion error occurs. The line re-
mains active until the error
code is reset to 0 (by a query
with
6
InMotion
The selected digital output line
is active as long as the selec-
ted axis is in motion.
7
POffset
The first trigger pulse is output
when the axis has reached the
position specified with Trigger-
Position (<CTOPam> 10). The
next trigger pulses are output
respectively when the axis po-
sition equals the sum of the
last valid trigger position and
the distance specified by Trig-
gerStep (<CTOPam> 1).
Trigger output ends when the
axis position exceeds the val-
ue specified by StopThreshold
(<CTOPam> 9).
9 COMMAND REFERENCE
PZ285EN
‒
1/30/2019
122
M O T I O N | P O S I T I O N I N G