Best: 320 sq.ft.
The coverage range of the sensor switch is specified and illustrated
Control Panel Cover
LED Indicator
OFF OCC VAC
TIME
TEST
10
20
30
Min
Min
Min
RANGE
LIGHT
3
3
2
Mounting Yoke
Fresnel Lens
OFF OCC VAC
Figure 4
4
1
2
4
1
- 01-
-03-
-02-
DESCRIPTION
DWOS
Voltage ....................................................................…… 120VAC,60Hz
Incandescent ........................................................................… 800W
Motor ...................................................................................…… 1/4Hp
Time Delay..........................................................…… 15Sec to 30Mins
SPECIFICATIONS
SENSOR-DWOS
Indoor PIR Motion
Occupancy Sensor
Fluorescent................................................................................... 800VA
INSTALLATION
Turn off the circuit breaker before installation;
WARNING:
Do not exceed electrical ratings.
Line(Hot), Red lead to Load wire, White lead to Neutral wire, Green
2. Gently position wires in wall box, attach sensor switch to the box.
3. Mount device “TOP”up.
Neutral
White
Hot
Black
Ground
Green
Load
Red
Neutral(White)
Load
4. Restore power at circuit breaker or fuse, wait
6. Locate the adjustment knobs on the control panel to perform test
ADJUSTMENT
INSTALLATION INSTRUCTIONS
Light Level.................................................................. 30 Lux--Daylight
Indoor use only;
Wiring Diagram:
Figure 2
OCC
Mode
OFF
VAC
Description
Circuit is permanently opened.
after set time delay.
Position
Left
Center
Right
Occupancy Mode:
Vacancy Mode: Manual On only,
automatic Off after set time delay.
React to the push-button
Manually toggles
None
Manually toggles
Automatic On, automatic Off
1. Connect lead wires as WIRING DIAGRAM (see Figure 2): Black lead to
the light to turn off eventhough someone is still in the detection area.
The passive infrared sensors work by detecting the difference between
heat emitted from the human body in motion and the background space.
in Figure 1. Large objects and some transparent barriers like glass
windows will obstruct the sensors' view and prevent detection, causing
Coverage Area
Band switch prescription.
The sensor switch can turn a load on and hold it as long as the sensor
detects occupancy. After no motion is detected for the set time delay, the
load turns off automatically. The sensor switch has one relay (equal to
single pole switch), also includes Ambient Light Level Sensor.
5. Remove the small cover plate. (Illustrated as Figure 3. )
7. Replace the small cover plate after testing and adjustment.
8. Attach the wallplate.
Figure 3
(switched off)
On / Off the load.
On/Off the load.
and adjustment.(Illustrated as Figure 3. )
Default position: 15 Seconds (Test mode)
Adjustable: from 15 Seconds to 30 Minutes (clockwise)
Default position: Center at 65%
Adjustable: 30% (Position 1) to 100% (Position 4)
Note: Turn toward right for greater room space.
Turn toward left to avoid false alert in smaller room and near
the door way or heat source.
Default position: Daylight (100% at position 4)
Adjustable: Daylight to 30Lux (Counter clockwise)
Note: to avoid wasting energy by turn-on the light under daylight.
Time Delay knob
Sensor Sensitivity Range Knob
Ambient Light Level Knob
lead to Ground.
Figure 1
one
minute.
(Push Button)
Operation Temperature...................................................... 32 F--131 F
Regular: 800 sq.ft.
Maximum: 1200 sq.ft.
40'
Top View
20'
10'
20'
10'
20'
5'
4'