Best: 320 sq.ft.

The coverage range of the sensor switch is specified and illustrated 

Control Panel Cover

LED Indicator

OFF  OCC  VAC

TIME

TEST

10

20

30

Min

Min

Min

RANGE

LIGHT

3

3

2

Mounting Yoke

Fresnel Lens

OFF  OCC  VAC

Figure 4

4

1

2

4

1

- 01-

-03-

-02-

DESCRIPTION

DWOS

       

 

Voltage ....................................................................……  120VAC,60Hz        

Incandescent ........................................................................…  800W

Motor  ...................................................................................……  1/4Hp        

Time Delay..........................................................……  15Sec to 30Mins  

SPECIFICATIONS

SENSOR-DWOS

Indoor PIR Motion 

Occupancy Sensor

Fluorescent................................................................................... 800VA

 

INSTALLATION

 Turn off the circuit breaker before installation;  

WARNING:

Do not exceed electrical ratings.

 Line(Hot), Red lead to Load wire, White lead to Neutral wire, Green 

2. Gently position wires in wall box, attach sensor switch to the box.

3.  Mount device “TOP”up.

Neutral

White

Hot

Black

Ground

Green

Load

Red

Neutral(White)

Load

4.  Restore power at circuit breaker or fuse, wait

6.  Locate the adjustment knobs on the control panel to perform test 

ADJUSTMENT

INSTALLATION INSTRUCTIONS

Light Level..................................................................  30 Lux--Daylight

Indoor use only;

Wiring Diagram:

Figure 2

OCC  

Mode

OFF

VAC 

Description

Circuit is permanently opened.

after set time delay. 

Position

Left

Center

Right

Occupancy Mode:

Vacancy Mode: Manual On only, 

automatic Off after set time delay.

React to the push-button

Manually toggles 

None

Manually toggles 

Automatic On, automatic Off 

1. Connect lead wires as WIRING DIAGRAM (see Figure 2): Black lead to 

the light to turn off  eventhough someone is still in the detection area.

The passive infrared sensors work by detecting the difference between

heat emitted from the human body in motion and the background space.

in Figure 1. Large objects and some transparent barriers like glass 

windows will obstruct the sensors' view and prevent detection, causing

Coverage Area

Band switch prescription.

The sensor switch can turn a load on and hold it as long as the sensor

detects occupancy. After no motion is detected for the set time delay, the 

load turns off automatically. The sensor switch has one relay (equal to 

single pole switch), also includes Ambient Light Level Sensor. 

5.  Remove the small cover plate.  (Illustrated as Figure 3. )

7. Replace the small cover plate after testing and adjustment.

8. Attach the wallplate.

Figure 3

(switched off)

On / Off the load.

On/Off the load.

and adjustment.(Illustrated as Figure 3. )

Default position: 15 Seconds (Test mode)

Adjustable: from 15 Seconds to 30 Minutes (clockwise)

Default position: Center at 65%

Adjustable: 30% (Position 1) to 100% (Position 4)

Note: Turn toward right for greater room space.

      Turn toward left to avoid false alert in smaller room and near 

 the door way or heat source.  

Default position: Daylight (100% at position 4)

Adjustable: Daylight to 30Lux (Counter clockwise) 

Note: to avoid wasting energy by turn-on the light under daylight.

Time Delay knob

Sensor Sensitivity Range Knob

Ambient Light Level Knob

lead to Ground.

Figure 1

 one

 minute.

(Push Button)

Operation Temperature...................................................... 32 F--131 F

Regular: 800 sq.ft.

Maximum: 1200 sq.ft.

40'

Top View

20'

10'

20'

10'

20'

5'
4'