background image

 

 

 

 

 

 

 

www.phywe.com, © All rights reserved 

 

12945-00 / 2821

 

Operating 
instructions 

Cobra SMARTsense Dual Photogate  

 

 
 

12945-00 
12945-01 

 

PHYWE Systeme GmbH & Co. KG 
Robert-Bosch-Breite 10 
D

–37079 Göttingen 

 
Telefon 

+49 (0) 551 604–0 

Fax   

+49 (0) 551 604–107 

E-mail 

[email protected] 

Internet 

www.phywe.com 

 

 

 

The unit complies 
with the applicable 
EC-guidelines 
 

 

 

  

 

Fig. 1: 12945-00 Cobra SMARTsense Dual Photogate 

TABLE OF CONTENTS 

1

 

SAFETY PRECAUTIONS

 

2

 

PURPOSE AND CHARACTERISTICS

 

3

 

FUNCTIONAL AND OPERATING ELEMENTS

 

4

 

NOTES ON OPERATION

 

 

HANDLING

 

6

 

TECHNICAL DATA

 

7

 

SCOPE OF DELIVERY

 

8

 

ACCESSORIES

 

9    CONFORMITY

 

10

 

DISPOSAL

 

 

1  SAFETY PRECAUTIONS 

 

 

Carefully  read  these  operating  instructions  completely 
before  operating  this  instrument.  This  is  necessary  to 
avoid damage to it, as well as for user-safety. 

 

Only use the instrument for the purpose for which it was 
designed. 

 

Only use the instrument in dry rooms in which there is no 
risk of explosion. 

 

Protect  the  instrument  from  dust, moisture and  vapours. 
Use a slightly moist lint-free cloth to clean the instrument. 
Do not use aggressive cleaning agents or solvents. 

 

Take care that no liquid penetrates in through the hous-
ing  openings,  as  such  penetration  would  result  in  dam-
age to Sensor. 

 

Do not open the unit. 

2  PURPOSE AND CHARACTERISTICS 

The sensor is used to measure kinematic physical quantities 
such as time, movement, speed and acceleration. The 
measured values are transmitted via Bluetooth or USB to any 
end devices such as tablets, smartphones etc. 

 

Caution! 

Содержание Cobra SMARTsense Dual Photogate

Страница 1: ...perating instructions completely before operating this instrument This is necessary to avoid damage to it as well as for user safety Only use the instrument for the purpose for which it was designed Only use the instrument in dry rooms in which there is no risk of explosion Protect the instrument from dust moisture and vapours Use a slightly moist lint free cloth to clean the instrument Do not use...

Страница 2: ...lp of the grating continuous data acquisition can be carried out e g for drop tests Fig 3 3 7 Incremental wheel base only in 12945 01 Fit the base to the housing of the photogate using the screw provided Fig 4 and then push the incremental wheel onto the base until a click is heard Fig 5 Fig 4 Fig 5 4 NOTES ON OPERATION This device fulfils all of the technical requirements that are compiled in cur...

Страница 3: ...and that the soft ware is allowed to access the interface After the sensor has been selected in the software the LED flashes green to indicate that the connection has been estab lished correctly After the sensor has been coupled with the software the sensor is no longer visible to other users in the software and therefore can no longer be selected If the sensor is switched on and not connected it ...

Страница 4: ...ly materials that should be returned to the local recycling sta tions PHYWE Systeme GmbH Co KG Abteilung Kundendienst Robert Bosch Breite 10 D 37079 Göttingen Telefon 49 0 551 604 274 Fax 49 0 551 604 246 Do not dispose of this product with normal household waste If this unit needs to be disposed of please return it to the address that is stated below for proper disposal PHYWE Systeme GmbH Co KG h...

Отзывы: