5.3 Start-up 

Switch the sensor on by pressing the on-button for more than 
3  seconds.  The  Bluetooth  LED  lights  up  red.  Start  the  soft-
ware and select the sensor. 
 

9-digit 

code 

is 

printed  on  the  back  of 
the 

sensor 

(Fig.6). 

The last 4 digits of the 
code  are  displayed  as 
sensor  designation  in 
the  software  (Fig.7). 
This  enables  an  exact 
assignment 

of 

the 

sensors 

with 

the 

software.  
 

   

 

 

 

 

Fig. 6 

 
 
 

   

 

 

 

   

 

   

 

 

 

 

Fig. 7 
 

Selection of the sensor via the Bluetooth interface 

Make  sure  that  the  Bluetooth  interface  is  activated  on  the 
terminal  device  (PC/Tablet/Smartphone)  and  that  the  soft-
ware is allowed to access the interface.  
 
After the sensor has been selected in the software, the LED 
flashes green to indicate that the connection has been estab-
lished  correctly.  After  the  sensor  has  been  coupled  with  the 
software, the sensor is no longer visible to other users in the 
software, and therefore can no longer be selected.  
 
If the sensor is switched on and not connected, it switches off 
automatically after 5 minutes. 
 

Selection of the sensor via the USB interface 

For  this  purpose  the  sensor  must  be  plugged  into  the  USB 
port  of  the  end  device.  It  is  not  necessary  to  switch  on  the 
sensor.  The  sensor  is  automatically  recognized  and  dis-
played. It can be selected and connected directly. 
 
 

5.4 Recording of measurement data 

 
Press  the  bellows  (fig.2  no.2)  quickly  and  repeatedly  until  a 
pressure  of  150-170  mmHg  is  reached.  Start  the  measure-
ment in the software and now slowly open the release valve 
(fig.2 no.3) until the pressure is continuously reduced slightly. 
If  the  pressure  has  fallen  below  50  mmHg  stop  the  meas-
urement and open the release valve completely 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

   

 

 

Fig. 8 

 

The  pulse  pressure  signal  (∆p)  superimposed  on  the  falling 
pressure  is  normalised  to  1.0  at  its  maximum  amplitude 
(MAP). 
 
The  systolic  pressure  (SAP)  is  on  the  falling  pressure  curve 
at the point where ∆p has an amplitude of 0.5 (before MAP).  
 
Diastolic pressure (DAP) is normalised to 0.85 (after MAP) on 
the falling pressure curve at the point where ∆p has fallen to 
the amplitude of 0.85 (after MAP). 

6  TECHNICAL DATA  

Operating temperature range: 5 - 40°C 
Rel. humidity < 80% 
 
Measuring range 
Resolution 
Accuracy 

0… 375 mmHg  

0.05 mmHg 

± 3 mmHg 

Max. date rate 
Battery capacitiy 
Max. wireless range (open field) 

500 Hz 

250 mAh 

30 m 

Dimensions (length x width x height) 

190 x 55 x 24 mm 

Weight 

205 g 

7  SCOPE OF DELIVERY 

The extent of delivery is as follows  

 

Cobra SMARTsense Blood Pressure 

12944-00 

 

USB cable type C 

07935-00 

 

Blood pressure cuff with double tube system 
and bellows 

 

 

Operating instructions 

8  ACCESSORIES 

The following accessories are available: 

 

Cobra SMARTlink 

12999-99 

 

USB-charger 

07934-99 

 

USB cable type C 

07935-00 

 

USB-Bluetooth-Adapter 

07936-00 

 

Software measureLAB 

14580-61 

 

Free measureApp available from supplier portals 

iOS 

 

Android 

 

Windows 

 

 

9    CONFORMITY 

 

 

 
 
 

 

 

Black 

PHYWE Systeme GmbH & Co.KG hereby 
declares that the radio system type 12944-
00 complies with the 2014/53/EU directive. 
The complete text of the EC Declaration of 
Conformity is available at the following In-
ternet address:  
www.phywe.com/en/ec-declaration 
 