6.1 Diagnostics by the LEDs
The LEDs indicate the status and error of the EXAM01 module:
LEDs
left
right
off
No power supply available
green
Logic power
OK
24 V power OK
6.2 Parameterising the Module
When using encoders, the corresponding
phyLOGIC
TM
parameters
P34
to
P39
should be
checked and set.
For the external power stage setting, please note as follows:
External power stage
(i.e. MCD+, MSX+,ZMX+,.)
Parameter
without ServiceBus
connection
P40 to P45
have no function
the settings (current, step
resolution) should be
made with the rotary or
DIP switches.
is connected via I4XM01
module to the ServiceBus
P40 to P44 settings
acc. to
the parameter list
P45
is invalid
P45
: Distribution of step
resolution (0 to 15)
according to the power
stage table (see power
stage manual)
For a general overview of the parameters:
Further manual
Detailed information on this subject is in a supporting manual:
“
phyLOGIC
TM
Command Reference
for the
phyMOTION
TM
Controller”
Information about positioning you’ll find in:
Further manual
Detailed information on this subject is in a supporting manual:
“Principles of Positioning of the Stepper Motor Controllers“