Manual EXAM01
MA 1277-A011 EN
16
5.2 Electrical Installation
Ensure sufficient bending radius of the cables during installation. Do not lay the cables in
tension or bend them.
We recommend labelling the mating connectors to prevent interchanging the connectors.
If all the connections are made, the last step is to plug in the power supply to the mains.
5.2.1 Connectors - Overview
Connector
Number
of pins
Connector on
the module
(Phoenix)
Mating
connector
Phoenix
Mating
connector
ID number
Encoder X1
1x10
MCDN1,5/10-G1-
3,5P26
FMC1,5/10-ST-
3,5
10013217
Limit switches X2
1x10
MCDN1,5/10-G1-
3,5P26
FMC1,5/10-ST-
3,5
10013217
Temperature
evaluation X3/X4
2x2
MCDN1,5/2-G1-
3,5P26
FMC1,5/2-ST-3,5 10007077
Control signals
X5/X6
2x8
MCDN1,5/8-G1-
3,5P26
FMC1,5/8-ST-3,5 10005881
The mating connector is included in delivery of the module and is usually plugged into the
module at the factory.
i
CAUTION
– Possible damage!
Damage of the module by wrong connection.
- Do not exchange the 10 pin limit switch connector with the
10 pin connector for the encoder evaluation.