phytron
13
MA 1277-A011 EN
4.4 Functions
Interface between stepper motor indexer and external power stage
Requires an upstream installed indexer (i.e. I4XM01)
Outputs Control pulses/Direction/Boost and Enable to an external power stage
External stepper motor power stage with ServiceBus can be diagnosed and
parameterised online via the interface on the indexer module (i.e. I4XM01).
3 Limit/reference switches
Evaluation of up to three limit switches/reference switches (PNP- NOC/NCC)
Option: Encoder evaluation
The evaluation of the following encoders depends on the selected sub module:
- with ECAS01 sub module: incremental or SSI
- with ECES01 sub module: EnDat, incremental or SSI
- with ECBS01 sub module: BiSS, incremental or SSI
- with ECMS01 sub module: Resolver, LVDT or RVDT
Option: Motor temperature evaluation
The evaluation of Pt100 temperature sensors (with PTS01 sub module) or K types
(with KTS01 sub module) is possible depending on the selected sub module.