9.2 Error Output
The Error output is active high to detect power failure and cable break.
This output is active, when the following limits are exceeded or are fallen below.
Simultaneously, the motor is deactivated:
Limits
Error message
Motor current
> 25.2 A
Overload
Supply voltage
< 40 V or > 160 V
Supply failure
Heat sink temperature
> 85°C
Overtemperature
The red LED OVERLOAD shines e.g. in case of motor short-circuit or if the time delay
during deceleration is too long.
The red LED SUPPLY FAILURE shines, when the supply voltage is out of the admissible
range 40...160 V. Danger of destroying the component in case of 200 V supply voltage!
The power stage needs sufficient time for cooling in case of ‚OVERTEMPERATURE’
(>85°C).
The supply voltage must powered off to reset the protective circuit after activation. Switch
on again only then, as soon as all LEDs are off!
Alternatively, it is possible to plug the J1 jumper on position Reset and activate the Reset
signal (low active) via pin 30c of the connector.