phytron
33
MA 2107-A005 EN
Jumper position
Activation
:
Jumper position
Reset
:
Fig. 15: Board with J1 jumper
The power stage is set to a defined initial state with Reset =0 (low active), that means that
all error messages and the ring counter are reset. Then, the ring counter is in basic
position. Both motor phases are energized by the same current value in basic position
independent of the step resolution.
Fig. 16: Motor phases in basic position (half step)