Technical Data
Error
Supply voltage < 40 V
DC
or >
160 V
DC
Overtemperature (T > 85° C)
Overcurrent, short circuit
The power stage is deactivated in case of an error message.
Cooling
Fan with 50 m
3
/h
air flow
Ambient
temperatures
Operation: 4 to +40 °C *)
Storage: –25 to +55 °C
Transport: –25 to +85 °C
*) We recommend an additional cooling in case of higher
operation temperatures.
Environmental
requirements
The MSX has been designed for degree of pollution 2 acc. to
EN 50178.
Admissible heat sink
temperature
max. 85 °C
The power stage is deactivated if the admissible heat sink
temperature is exceeded. The LED shines red.
Maximum motor lead
length
max. 50 m
Lead cross section of
the motor cable
Dependent on the motor current and the motor lead length:
0.1 mm
2
per 1 Ampere motor current
Connector
32-pin connector acc. to DIN 41 612, version D
Weight with front panel
about 970 g