The phyCORE-P8xC51Mx2 on the Development Board LD 5V
PHYTEC Messtechnik GmbH 2005 L-602e_3
55
The components at U11 and U12 guarantee electronic protection
against overvoltage and excessive current draw at pin 6 of P1A; in
particular:
•
Load detection and controlled voltage supply switch-on:
In order to ensure clear detection of the switch-on condition,
the connected device should cause a current draw of at least 10
mA at pin 6. The controlled voltage supply switch-on prevents
voltage drop off on the phyCORE Development Board LD 5V.
•
Overvoltage Protection:
If the voltage at pin 6 exceeds the limiting value that can be
provided by the phyCORE Development Board LD 5V, the
voltage at pin 6 will be switched off immediately. This prevents
damage to the phyCORE Development Board LD 5V as well as
connected modules and expansion boards.
•
Overload Protection:
If the current draw at pin 6 exceeds the limiting value of
approximately 150 mA, the voltage at pin 6 will be switched off
immediately. This prevents damage to the phyCORE
Development Board LD 5V and its power adapter caused by
current overload.
This configuration option provides the following possibility:
Jumper
Setting
Description
JP24
2 + 3
Electronically protected 5 V at pin 6 for supply of
external devices connected to P1A
Table 27:
JP24 Power Supply to External Devices Connected to P1A on the
Development Board
Содержание phyCORE-P8xC51Mx2
Страница 1: ...A product of a PHYTEC Technology Holding company phyCORE P8xC51Mx2 Hardware Manual Edition April 2005...
Страница 22: ...phyCORE P8xC51Mx2 14 PHYTEC MMesstechnikGmbH 2005 L 602e_3 Figure 7 Location of the Jumpers Bottom View...
Страница 46: ...phyCORE P8xC51Mx2 38 PHYTEC MMesstechnikGmbH 2005 L 602e_3...
Страница 50: ...phyCORE P8xC51Mx2 42 PHYTEC MMesstechnikGmbH 2005 L 602e_3...
Страница 82: ...Published by PHYTEC Messtechnik GmbH 2005 Ordering No L 602e_3 Printed in Germany...