2. The Boot input of the phyCORE-P8xC51Mx2 can also be perma-
nently connected to VCC. This spares pushing the Boot button
during a hardware reset or power-on.
Jumper
Setting
Description
JP28
2 + 4
Boot input connected permanently with VCC.
FlashTools are always started with Reset button or
with connection of the power supply
Table 23:
JP28 Configuration of a Permanent FlashTools Start Condition
Caution:
In this configuration, a regular reset, hence normal start of your
application, is not possible. The FlashTools firmware is started every
time. This is useful when using an emulator.
3. It is also possible to start the FlashTools via external signals
applied to the DB-9 socket P1A. This requires control of the signal
transition on the Reset line (/RESIN) via pin 7 while a static high-
level is applied to pin 4 for the Boot signal.
Jumper
Setting
Description
JP22
1 + 2
Pin 7 (CTS) of the DB-9 socket P1A as Reset signal
for the phyCORE-P8xC51Mx2
JP23
1 + 2
Pin 4 (DSR) of the DB-9 socket P1A as Boot signal
for the phyCORE-P8xC51Mx2
JP10
2 + 3
High-level Boot signal connected with the Boot input of
the phyCORE-P8xC51Mx2
Table 24:
JP22, JP23, JP10 Configuration of Boot via RS-232
Caution:
When using this function, the following jumper setting is not allowed:
Jumper
Setting
Description
JP10
1 + 2
Jumper setting generates low-level on Boot input
of the phyCORE-P8xC51Mx2
Table 25:
Improper Jumper Settings for Boot via RS-232
Содержание phyCORE-P8xC51Mx2
Страница 1: ...A product of a PHYTEC Technology Holding company phyCORE P8xC51Mx2 Hardware Manual Edition April 2005...
Страница 22: ...phyCORE P8xC51Mx2 14 PHYTEC MMesstechnikGmbH 2005 L 602e_3 Figure 7 Location of the Jumpers Bottom View...
Страница 46: ...phyCORE P8xC51Mx2 38 PHYTEC MMesstechnikGmbH 2005 L 602e_3...
Страница 50: ...phyCORE P8xC51Mx2 42 PHYTEC MMesstechnikGmbH 2005 L 602e_3...
Страница 82: ...Published by PHYTEC Messtechnik GmbH 2005 Ordering No L 602e_3 Printed in Germany...