![Phytec phyCORE-MCF548x Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/phytec/phycore-mcf548x/phycore-mcf548x_hardware-manual_1554126073.webp)
phyCORE Development Board PCM-982
PHYTEC Messtechnik GmbH 2005 L-645e_1
65
10.3.4
First CAN Interface at Plug P1A
Plug P1A is the bottom plug of the double DB-9 connector at P1. P1A
is connected to the first CAN interface (CAN_0) of the
phyCORE-MCF548x via jumpers. Depending on the configuration of
the CAN transceivers and their power supply, the following two
configurations are possible:
1.
CAN transceiver on the phyCORE-MCF548x is populated and the
CAN signals from the module extend directly to plug P1A.
Jumper
Setting
Description
JP1
1 + 2
Pin 7 of the DB-9 plug P1A is connected to CAN_H0
from on-board transceiver on the phyCORE module
JP2
1 + 2
Pin 2 of the DB-9 plug P1A is connected to CAN_L0
from on-board transceiver on the phyCORE module
Table 14:
Jumper Configuration for CAN Plug P1A Using the CAN
Transceiver on the phyCORE-MCF548x
1
2
3
4
7
6
5
8
9
Pin 7 CAN_H0 (non-isolated)
Pin 2 CAN_L0 (non-isolated)
Pin 6 CAN_GND
Pin 3 CAN_GND
Figure 17:
Pin Assignment of the DB-9 Plug P1A (CAN Transceiver on
phyCORE-MCF548x, Front View)
Содержание phyCORE-MCF548x
Страница 1: ...A product of a PHYTEC Technology Holding company phyCORE MCF548x Hardware Manual Edition January 2005 ...
Страница 8: ...phyCORE MCF548x PHYTEC Messtechnik GmbH 2005 L 645e_1 ...
Страница 30: ...phyCORE MCF548x 22 PHYTEC Messtechnik GmbH 2005 L 645e_1 ...
Страница 40: ...phyCORE MCF548x 32 PHYTEC Messtechnik GmbH 2005 L 645e_1 ...
Страница 44: ...phyCORE MCF548x 36 PHYTEC Messtechnik GmbH 2005 L 645e_1 ...
Страница 104: ...Published by PHYTEC Messtechnik GmbH 2005 Ordering No L 645e_1 Printed in Germany ...