PHYSITEMP PTM1 Скачать руководство пользователя страница 1

physitemp

 

 

Operating

 Manual

 

 

Portable Temperature Meter

 

 

 

 

 

 
 
 
 
 
 

 

PTM1

Содержание PTM1

Страница 1: ...physitemp Operating Manual Portable Temperature Meter PTM1...

Страница 2: ...2...

Страница 3: ...3...

Страница 4: ...S FUNCTION 5 MODEL PTM1 MODES 7 A MEASURE mode 7 B MAX mode 8 C MIN mode 8 D HOLD mode 8 E SETTING mode 8 a AM PM 9 b Hour Min Sec 9 c Month Day Year 9 d ABS REL 9 e C F 10 f TYPE K J or T 10 g OFFSET...

Страница 5: ...ures include long battery life and 50 60Hz AC noise rejection This meter is user friendly for field industrial and laboratory applications INITIAL INSPECTION Carefully unpack the unit and accessories...

Страница 6: ...cover and make sure to secure the two screws for the water tight feature Note Press the ON OFF key to turn the unit on If the unit is running then you can press the ON OFF key to turn the unit off Th...

Страница 7: ...LL mode In the SETTING mode press this key to move back to the previous setting In the RECALL mode press this key to exit the RECALL mode and return to the MEASURE mode CLEAR RIGHT CLEAR In the MEASUR...

Страница 8: ...mode When user powers on the model PTM1 the MEASURE mode screen will appear The instrument will return to this mode once you exit from other modes Only in the MEASURE mode the user can press the SAVE...

Страница 9: ...e reading it has captured since the last time the instrument has been cleared The instrument will display 2 screens one with time and the other with date The user can press the CLEAR key to clear the...

Страница 10: ...o change the flashing value or press the RIGHT key to move to the next date setting After the Year setting press the RIGHT key to move to ABS REL setting Press the LEFT key to move back to the previou...

Страница 11: ...s the min max at 03 00 00AM and the last max recorded occurred at 04 00 00AM the next day after more than 1 day the recorded elapsed time will be 01 00 00 e C F Press the UP or DOWN key to change to C...

Страница 12: ...e Press the LEFT RECALL key again to exit the RECALL mode and return to the MEASURE mode When the instrument switches to the RECALL mode it will first display the last data saved by the user Three scr...

Страница 13: ...ument s range for the thermocouple type sensor used b Probe not properly connected Change sensor with proper temperature range Check probe connection ovEr OVER MAX MAX Unit recorded an over temperatur...

Страница 14: ...FS 1 4 F 0 1 FS 0 7 C K 393 F to 2500 F 201 C to 1371 C 1 F 1 C 0 1 FS 1 4 F 0 1 FS 0 7 C T 393 F to 752 F 201 C to 400 C 1 F 1 C 0 1 FS 1 4 F 0 1 FS 0 7 C Cold Junction Compensation Error 0 05 C C 0...

Страница 15: ...stomer will be covered by Physitemp Damage due to misuse or accidental breakage is not covered Temperature probes are considered expendable and are not covered by this warranty unless found to be defe...

Отзывы: