LIFEPAK CR Plus/EXPRESS Defibrillator
Preventive Maintenance
Replacing the QUIK-PAK Electrodes
Use a new set of QUIK-PAK electrodes on each patient. Replace the
QUIK-PAK electrodes after each use or when the Use By date is passed.
Replace the QUIK-PAK electrodes and
at the
same time because their Use By date is the same. Discard used electrode pads
and any unused, spare electrode pads according to recycling instructions.
To replace the QUIK-PAK electrodes:
1. Open the lid (voice prompts will begin).
2. Press and hold the
LID RELEASE/ON-OFF
button for approximately two seconds
to turn off the defibrillator.
3. Unplug the electrode connector.
4. Remove the electrode packet anchor pin from the slot in the defibrillator.
5. Inspect the new electrode packet and confirm that the Use By date has not
passed.
6. Slide the electrode anchor pin into the slot on the defibrillator.
7. Plug in the new electrode connector.
(Continued on next page)
7-6