14 Hardware Interface
An example of improper wiring that causes a ground loop is shown in Fig. 14.15.
Isolator
ISO_IN
ISO_GND
Ground Loop
CAMERA_GND
Ground plane
voltage difference
Connecting CAMERA_GND and ISO_GND
the wrong way, ground loop!
Figure 14.15: Improper I/O wiring causing a ground loop