4.3 Frame Control
F
r a m e 1
. . . .
F r a m e N
A
c q u i s i t i o n A c t i v e
A
c q u i s i t i o n S t a r t
T r i g g e r 1
A c q u i s i t i o n E n d
T r i g g e r 1
F r a m e
T r i g g e r
W a i t
F r a m e
T r i g g e r
W a i t
A c q u s i t i o n
T r i g g e r
W a i t
A c q u i s i t i o n S t o p ( )
A c q u s i t i o n
T r i g g e r
W a i t
A c q u i s i t i o n S t a r t ( )
F r a m e B u r s t S t a r t
T r i g g e r 1
F r a m e B u r s t E n d
T r i g g e r 1
( o p t i o n a l )
F r a m e
A c t i v e
F r a m e S t a r t
T r i g g e r 1
F r a m e
A c t i v e
F r a m e
T r i g g e r
W a i t
F r a m e 1
A c q u i s i t i o n S t a r t T r i g g e r M o d e = O n
A c q u i s i t i o n E n d T r i g g e r M o d e = O n
F r a m e S t a r t T r i g g e r M o d e = O n
F r a m e B u r s t S t a r t T r i g g e r M o d e = O n
E x p o s u r e M o d e = T i m e d
Figure 4.7: Triggered Acquisition of a Burst of Frame and of a single Frame
4.3.4
Frame Control Output Signals
The frame control block has the following output signals:
Frame Trigger Wait
An asserted frame trigger wait indicates, that the frame control is waiting
for a frame start trigger (see Section 4.3.1), frame burst start trigger (see Section 4.3.2) or
an exposure start trigger (see Section 4.4.2).
Frame Active
An asserted frame active signal indicates, that one or more frames are being
captured.
Frame Start
The frame start is an event, which is generated, when a new frame starts.
Frame End
The frame end is an event, which is generated, when a frame is finished.
Frame Burst Start
The frame burst start is an event, which is generated, when a new burst of
frame starts.
Frame Burst End
The frame burst end is an event, which is generated, when a burst of frame is
finished.
Frame Trigger
The frame trigger is an event, which is generated, when a frame is started by a
frame start trigger (see Section 4.3.1), by a frame burst start trigger (see Section 4.3.2) or
by an exposure start trigger (see Section 4.4.2).
Frame trigger wait and frame active status signal are routed to the I/O control block and can
there be selected for output on the physical output line or on one of the available leds. Frame
start, frame end and frame trigger event can be used to trigger or to control other function in
the camera, like counter and timer.
MAN085 04/2021 V1.3
33 of 151
Содержание Luxima DR4-D1280-L01-FB
Страница 8: ...CONTENTS 8 of 151 MAN085 04 2021 V1 3...
Страница 12: ...1 Preface 12 of 151 MAN085 04 2021 V1 3...
Страница 42: ...4 Image Acquisition 42 of 151 MAN085 04 2021 V1 3...
Страница 52: ...5 Counter Timer 52 of 151 MAN085 04 2021 V1 3...
Страница 84: ...12 Pixel Data Processing 84 of 151 MAN085 04 2021 V1 3...
Страница 94: ...12 Pixel Data Processing 94 of 151 MAN085 04 2021 V1 3...
Страница 98: ...13 Precautions 98 of 151 MAN085 04 2021 V1 3...
Страница 128: ...16 Troubleshooting 128 of 151 MAN085 04 2021 V1 3...
Страница 134: ...19 Support and Repair 134 of 151 MAN085 04 2021 V1 3...
Страница 136: ...20 References 136 of 151 MAN085 04 2021 V1 3...
Страница 140: ...A Pinouts 140 of 151 MAN085 04 2021 V1 3...
Страница 150: ...C Use Cases 150 of 151 MAN085 04 2021 V1 3...