14.6 I/O Connector
14.6.2
Input Fault Detection
All inputs support a fault detection which signalises irregular conditions such as small
differential signals, shorts, opens, overvoltages and undervoltages. The fault condition of each
input can be read out by a software parameter. A fault condition remains active until it is
acknowledged by a software command.
Additionally Led S1 signalises the fault condition on LineIn0 and LineIn1. It turns on, when a
fault condition exists and turns automatically off when the input fault is resolved.
Section 14.2 lists the input range, the corresponding logic levels and fault conditions.
Unused inputs should be configured as single ended and the N-input must be
tight to ISO_GND in order not to get an I/O fault condition.
If an error condition has been detected on an input and signalized by the
Line-
Fault
parameter, it must be acknowledged by the
LineFaultAcknowledge
command
in order to use or reconfigure the corresponding input again.
Parameter
LineFaultUpdate
must be performed in order to update the error state.
14.6.3
Single-ended Line Input
LineIn0, LineIn1 or LineIn2 can be configured as single-ended input (Table 14.8 lists the
available standards). Fig. 14.5 shows two examples, how a single-ended configured input can
be used.
The inputs must be driven by a push-pull stage or an open drain output with a
pull-up resistor.
.
MAN085 04/2021 V1.3
107 of 151
Содержание Luxima DR4-D1280-L01-FB
Страница 8: ...CONTENTS 8 of 151 MAN085 04 2021 V1 3...
Страница 12: ...1 Preface 12 of 151 MAN085 04 2021 V1 3...
Страница 42: ...4 Image Acquisition 42 of 151 MAN085 04 2021 V1 3...
Страница 52: ...5 Counter Timer 52 of 151 MAN085 04 2021 V1 3...
Страница 84: ...12 Pixel Data Processing 84 of 151 MAN085 04 2021 V1 3...
Страница 94: ...12 Pixel Data Processing 94 of 151 MAN085 04 2021 V1 3...
Страница 98: ...13 Precautions 98 of 151 MAN085 04 2021 V1 3...
Страница 128: ...16 Troubleshooting 128 of 151 MAN085 04 2021 V1 3...
Страница 134: ...19 Support and Repair 134 of 151 MAN085 04 2021 V1 3...
Страница 136: ...20 References 136 of 151 MAN085 04 2021 V1 3...
Страница 140: ...A Pinouts 140 of 151 MAN085 04 2021 V1 3...
Страница 150: ...C Use Cases 150 of 151 MAN085 04 2021 V1 3...