Example
Create the RAID-1 virtual disk VD1 using two disk drives.
Create the RAID-50 virtual disk VD2 having three RAID-5 subvirtual disks, each
having three disk drives.
disks
disks
Specifies the disk drives by a range or list of IDs;
or for RAID 10, a colon-separated list of RAID-1
subvirtual disks; or for RAID 50, a colon-
separated list of RAID-5 subvirtual disks. For the
syntax to use, see “Disk Drive Syntax” on
page 24.
assigned-to a|b|auto
Optional. Specifies the controller to own the
virtual disk. To have the system automatically
load-balance virtual disks between controllers, use
auto
or omit this parameter.
spare
disks
Optional. Specifies up to four vdisk spares to
assign to a RAID 1, 3, 5, 6, 10, or 50 virtual disk.
For the syntax to use, see “Disk Drive Syntax” on
page 24.
chunk-size 16k|32k|64k
Optional. Specifies the chunk size in Kbyte. The
default is
64k
.
mode online|offline
Optional. Specifies whether the virtual disk is
initialized online or offline. The default is
online
.
name
Specifies a name for the new virtual disk. For the
syntax to use, see “Virtual Disk Syntax” on
page 25.
#
create vdisk level raid1 disks 1,3 VD1
#
create vdisk level r50 disks 1-3:4-6:7-9 VD2
Parameter
Description
Содержание RPC12 Series
Страница 1: ......
Страница 11: ...12 Phoenix RPC12 Series CLI Reference Manual September 2008...
Страница 29: ...30 Phoenix RPC12 Series CLI Reference Manual September 2008...
Страница 35: ...36 Phoenix RPC12 Series CLI Reference Manual September 2008...
Страница 78: ...Chapter 3 Command Descriptions 79 Related Commands Q show master volumes on page 180 Q show vdisks on page 208...
Страница 81: ...82 Phoenix RPC12 Series CLI Reference Manual September 2008 exit Description Exits the CLI session Syntax exit...
Страница 93: ...94 Phoenix RPC12 Series CLI Reference Manual September 2008 Related Commands Q show snapshots on page 196...
Страница 227: ...228 Phoenix RPC12 Series CLI Reference Manual September 2008...