Страница 3: ...dewertokin de Info dewertokin de Creation of a complete operating instruction manual for the entire end product These instructions are only intended to be used by the end product manufacturer They sho...
Страница 4: ...operation 7 2 4 Product labelling 8 3 Description of component 9 3 1 Device components 9 3 2 Layout of the CU155 DC Adapter connections 10 4 Technical Specifications 11 4 1 CU155 DC ADAPTER 11 5 Inst...
Страница 5: ...ention However unless oth erwise required by law we do not guarantee that the data images and drawings are accurate or complete nor do we accept liability for their contents We reserve the right to ma...
Страница 6: ...piration of all guarantee and warranty claims on the part of the end product manufacturer against DewertOkin 2 1 1 Improper usage Be sure to follow the notices below concerning improper usage You shou...
Страница 7: ...while installing the CU155 DC ADAPTER These rules and safety measures can be categorized as follows construction measures before the installation refer to the Ensuring operational reliability during i...
Страница 8: ...bel shown is an example the specifications for your CU155 DC ADAPTER may differ from this illustration Figure 1 Type label for the CU155 DC ADAPTER example CU155 DC ADAPTER Model name xxxxx ID No 29V...
Страница 9: ...also be connected using DIN 41529 plugs We reserve the right to make unannounced technical changes in the course of our con tinual product improvement process 3 1 Device components The CU155 DC ADAPT...
Страница 10: ...on scheme is individual and depends on the system specifica tions Figure 4 is only an example and shows you where the label is attached Figure 4 Position of the connection layout sticker on the CU155...
Страница 11: ...24VDC 0 12VDC Type of connection LSP socket DIN 41529 Protection class III Protection category IP00 X6 Protection category IPX6 Only when using mounted plugs with O rings sockets sealed with dummy pl...
Страница 12: ...CU 155 DC Adapter 72810 a 12 24 Figure 5 Top view CU155 DC ADAPTER dimensions in mm Figure 6 Front view CU155 DC ADAPTER dimensions in mm 44 157 107...
Страница 13: ...escribed below ACHTUNG Do not remove the dummy plugs from the sockets 2 and 3 on the CU155 DC ADAPTER Only remove the dummy plug from connecting socket 4 when adjusting the output voltage for connecti...
Страница 14: ...hich can be used to attach it to the end product with the appropriate screws for example M4 x 50 screws The CU155 DC ADAPTER should be mounted so that it lies flat against its supporting material In t...
Страница 15: ...2 3 Connecting the peripheral devices or LED lamp 1 If necessary unscrew both screws on the shield cover 2 Pull out the shield over from the guide slots 3 Connect the peripheral device or LED lamp to...
Страница 16: ...lly the connecting cables to the end product using sufficient strain relief and kink prevention methods Be sure that the design of the end product prevents the connecting cables from coming into conta...
Страница 17: ...from the guide slots 3 Remove the dummy plug off of socket 4 4 Use a screwdriver to set the proper voltage for your peripheral device Position 1 5VDC 2 9VDC 3 24VDC 0 12VDC 1 Re attach the dummy plug...
Страница 18: ...qualified specialists and are not for typical users of the end product 6 1 General notice Only drive and drive control units from DewertOkin should be connected to the CU155 DC ADAPTER since they have...
Страница 19: ...The drive is suddenly no longer capable of movement The thermal fuse on the trans former may have been triggered Please contact your supplier or sales agent The device fuse may have been triggered Ple...
Страница 20: ...ts for damage Check that all electrical cables and connections are firmly seated and correctly positioned At least every six months Periodic visual inspection for cable damage Check the connecting cab...
Страница 21: ...all corresponding national and regional environmental regulations when disposing of the CU155 DC ADAPTER The disposal of the end product is regulated in Germany by Elektro G internationally by the EU...
Страница 22: ...e 2014 35 EU Low Voltage Directive 2014 35 EU DELEGIERTE RICHTLINIE EU 2015 863 DER KOMMISSION vom 31 M rz 2015 zur nderung von Anhang II der Richtlinie 2011 65 EU des Euro p ischen Parlaments und des...
Страница 23: ...DewertOkin GmbH Weststra e 1 32278 Kirchlengern Germany Tel 49 0 5223 979 0 Fax 49 0 5223 75182 http www dewertokin de Info dewertokin de ID Nr 72810...