FL WLAN EPA
1-8
PHOENIX CONTACT
8099_en_02
•
Fix the EPA on the base plate using the two screws provided.
•
The two 4.5 mm bore holes can be used for mounting. Two steel clamps are provided
for mounting the EPA to a mast (25 - 85 mm).
1.7
FL WLAN EPA ... installation/interfaces
Figure 1-5
View and interfaces of the FL WLAN EPA ...
–
Fixing holes
Using these holes, you can install the FL WLAN EPA ... on a level surface using two
screws (e.g., 84-M3 X 30-8.8 cylinder head screws) (for drill hole spacing, see
–
Antenna
Devices
with
an internal antenna: these devices are supplied with a circular polarized
5-dB panel antenna. This design is particularly suitable in environments where many
reflections occur on metal. The internal antenna cannot be replaced. It is adapted to the
frequency band of the relevant product (2.4 GHz or 5 GHz).
Devices
without
internal antenna: the antenna technology used can be chosen by the
user.
–
Supply voltage connection
The supply voltage is connected via the 5-pos. M12 socket (plug on the device; for the
assignment, please refer to page 1-10).
NOTE:
Observe the approved operating temperatures of the EPA when using the EPA
outdoors. The device is designed for installation in protected outdoor areas (e.g., beneath
a porch). Direct sunlight may lead to overheating and permanent damage of the device.
Note
: observe the applicable regulations for using wireless devices outdoors.
Fixing holes
Internal circular
polarized antenna
Status and diagnostic
indicators
Mode button
Link Quality and
mode LEDs
LAN interface
Supply voltage
connection/switching input
7901001
RSMA antenna
connection (version)
7901001