Mounting
108366_en_01
PHOENIX CONTACT
3.3
Mounting
Proceed as follows to mount the safety switch to the safety equipment:
Mounting the sensor
1.
Screw the sensor to the fixed part of the safety equipment.
2.
Close the mounting slots using the caps.
Mounting the actuator
1.
At first, only loosely attach the actuator to the moving part of the safety equipment.
2.
Adjust the actuator:
–
According to the arrow alignment between the sensor and actuator
–
According to the required distances between the sensor and actuator
3.
Tighten the actuator.
4.
Close the mounting slots using the caps.
Tip:
in order to enable later exchange, use common screws when mounting the sensor.
Use the safety screws provided.
Observe the permissible tightening torque for the screws.
See Section “Technical data” on page 57.
The safety screws can only be used once.
After tightening, the screws cannot be removed again.