Product description and method of operation
108366_en_01
PHOENIX CONTACT
2.4.6
Switching states of the outputs
Switching states
The outputs have the following switching states when safety equipment is open or closed.
The switch-on state depends on the selected startup behavior.
Table 2-2
Switching states
Output
Safety equipment closed
Safety equipment open
–
Actuator within response area
–
Permissible coding
–
Start command present/auto-
start
–
Actuator within response area
–
Permissible coding
–
Start command not present
–
Actuator outside response
area
FO1A
FO1B
On
Off
Off
DGN
Off
On
On
Overview of the switching states in combination with the LED indicators for general states
and error messages:
See Section “LED status indicators and switching states” on page 43.