Overview
2338_en_O
PHOENIX CONTACT
7
I/O expansion modules are always connected on the right side of the base unit. For
example, a PNP or analog I/O expansion module can be added to an NPN base unit. A
female D-SUB 9 connector located on the left side of the module connects to a male D-SUB
9 connector on the right side of the base unit or previously installed I/O expansion module.
A maximum of three NLC-IO-… modules can be connected.
Figure 1-3
NLC-IO… expansion module type codes
1.1.3
Communication expansion modules
Communication expansion modules (NLC-COM-
tttt
) are used to place a control system on
a network. Appropriate connectors for the type of communication are included on the
NLC-COM-…. For instance, an Ethernet-capable module uses an RJ45 connector.
Different expansion modules are required for different network types but only one
communication expansion module can be connected to the base unit at a time (a second
network can be connected through the RS-232 or RS-485 base unit option module).
Communication expansion modules are always connected on the left side of the base unit.
A female D-SUB 9 connector located on the right side of the module connects to a male D-
SUB 9 connector on the left side of the base unit.
1.1.4
Option module
Base unit option modules (NLC-MOD-…) are placed in the appropriate slot on the base unit.
A variety of option modules are available to accomplish specific purposes.
The slots for NLC-MOD-… modules are located on the face of the base module. The slots
are numbered 1 or 2, so the proper option module can be placed in the proper slot.
nLC-IO-A-06I-04QRD-01A-4AI-2AO
Product Family
Module Type
Power Supply Type
A = AC
D = DC
X = AC/DC
Max Output Current*
00 = less than 1 amp
01 = 1 amp or less
05 = 5 amps or less
Output Type*
TN = Transistor, NPN
TP = Transistor, PNP
TX = Transistor, PNP and NPN
RD = Relay, DC
RA = Relay, AC
RX = Relay, AC or DC
Number of Digital Inputs*
Number of Digital Outputs*
Number of Analog Outputs*
Number of Analog Inputs*
* optional component
NOTE:
Option modules are not keyed to prevent entry into an incorrect slot. However, option
modules are not interchangeable between slots. Option modules intended for Slot 1 must
only be inserted in Slot 1, and option modules intended for Slot 2 must only be inserted in
Slot 2. Each slot is labeled on the face of the base unit, and each option module includes
a numeric indicator to indicate which slot is acceptable.
Содержание Nanoline NLC-035-024D-04I-02QRD-05A
Страница 1: ...User manual Installing and using Nanoline controllers UM EN NLC...
Страница 8: ...Nanoline 4 PHOENIX CONTACT 2338_en_O...
Страница 38: ...Nanoline 34 PHOENIX CONTACT 2338_en_O...
Страница 54: ...Nanoline 50 PHOENIX CONTACT 2338_en_O...
Страница 66: ...Nanoline 62 PHOENIX CONTACT 2338_en_O...
Страница 94: ...Nanoline 90 PHOENIX CONTACT 2338_en_O...
Страница 126: ...Nanoline 122 PHOENIX CONTACT 2338_en_O...