FL WLAN EPA
2-12
PHOENIX CONTACT
108452_en_02
•
Use the two screws provided to fix the EPA to the base plate.
•
The two 4.5 mm bore holes can be used for mounting. Two steel clamps are provided
for mounting the EPA to a mast (25 mm ... 85 mm).
2.2.3
Connectors
Figure 2-4
M12 connectors
Power connectors (M12 connectors, A-coded)
Table 2-1
M12 power connectors
Graphic
Pin
Function
1
Power (9 V DC ... 30 V DC)
2
Digital input ground
3
Power ground
4
Digital input + (9 V DC ... 30 V DC)
5
Functional ground
NOTE:
The signal line for the digital input must be carried in the same cable as power supply and
functional ground if the line length exceeds 3 meters.
Table 2-2
LAN power connectors
Graphic
Pin
Function
Color coding (T568B)
1
Transmit
Orange/white
2
Receive
Green/white
3
Transmit
Orange
4
Receive
Green