Connection examples
106377_en_04
PHOENIX CONTACT
37 / 68
7.3
Charging enabled with local release and charging
current reduction
Figure 7
-
3
Connection example 3
S1/DIP 1 = OFF
Charging station with Infrastructure Socket Outlet
S1/DIP 5 = ON
Charging current preset to 32 A
Locking
is carried out if the vehicle is detected at the charging station.
The
charging process
starts if locking is detected, switch k1 is closed, and status C is
present.
– If switch k2 is closed, the charging current (PWM signal) is reduced during this time
).