![Phoenix Contact EV Charge Control Basic Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/phoenix-contact/ev-charge-control-basic/ev-charge-control-basic_user-manual_1551421011.webp)
Connections, indicators, configuration switches
106377_en_04
PHOENIX CONTACT
11 / 68
2.2
Diagnostic and status indicators
Figure 2
-
2
Diagnostic and status indicators
Table 2
-
2
Diagnostic and status indicators
No. Name Meaning
Color
Status
Description
6
X1
Diagnos
-
tics
Reserved for future expansions
PWR
Power
Green
On
Charging controller ready
Flashing
(1 Hz)
Charging controller is starting up
CON
Connect
Yellow
On
Charging cable is connected to the charging station and the vehicle
Flashing
(1 Hz)
Charging cable is connected to the charging station and locked
ERR
Error
Red
On
Error
Flashing
(1 Hz)
Errors that originate at the vehicle or charging cable
CHR
Charging
Blue
On
Charging contactor closed
Flashing
(1 Hz)
Vehicle connected, charging current ready, PWM signal switched
on, charging contactor open
L N
PE GND 12V 12V
a
EN XR ML CCR IN OUT ERR CHG CON
C1 C2
A B SG
CP PP LD1 LD2 L0+ L0-
IO
R
ela
y
R
485
S
Outlet
Po
w
er
PWR
S1
S2
CON
ERR
CHR
6
Содержание EV Charge Control Basic
Страница 1: ...User manual EV Charge Control Basic Installing and starting up the charging controller ...
Страница 14: ...EV Charge Control Basic 14 68 PHOENIX CONTACT 106377_en_04 ...
Страница 34: ...EV Charge Control Basic 34 68 PHOENIX CONTACT 106377_en_04 ...
Страница 46: ...EV Charge Control Basic 46 68 PHOENIX CONTACT 106377_en_04 ...
Страница 69: ......