Field of application of the product
1.3.1
Intended use
The AXL SE PSDI8/3 Smart Element is designed for use within a PROFIsafe system. To do
so, the Smart Element is integrated in the Axioline F system via an Axioline F backplane.
The Smart Element is designed for the connection of:
– Suitable safe 1 or 2-channel sensors
Safety functions
The Smart Element performs the following safety functions:
– Safe reading
– Safe transmission of I/O signals
Achievable safety integrity
Within a system, the Smart Element can be used to achieve the following safety integrity
depending on the conditions of use:
– Up to SIL 3 in accordance with IEC 61508
– Up to SILCL 3 in accordance with EN 62061
– Up to Cat. 4/PL e in accordance with EN ISO 13849-1
Technical data and envi
-
ronmental conditions
Only use the Smart Element in accordance with the defined technical data and environmen
-
tal conditions.
See
“Technical data and ordering data” on page 75
Safety of personnel and
equipment
The safety of personnel and equipment can only be assured if the Smart Element is used
correctly.
1.3.2
Foreseeable misuse
1.3.3
Product changes
Modifications to hardware and firmware of the device are not permitted.
Incorrect operation or modifications to the device can endanger your safety or damage the
device. Do not repair the device yourself. If the device is defective, please contact
Phoenix Contact.
WARNING: Serious risks due to inappropriate use
There is a serious risk to the user and/or equipment if the Smart Element is used inappro
-
priately or not in accordance with the intended use, or if the Smart Element is subject to
tampering.