Application manual for PSRclassic and PSRmultifunction, and the modular safety relay system
PHOENIX CONTACT
102597_en_03
5.2.1
PSR-ESL4/3x1/1x2/B up to PL e/SIL 3
Two-channel light grid monitoring with manual reset (ESPE type 4)
Application example
–
Two-channel light grid monitoring
–
Cross-circuit detection via the light grid
–
Manual reset (S33, S34)
–
Feedback of contactor contacts K3 and K4 at S34
–
Stop category 0
–
Monitoring of external contactors
–
Safety level of the example up to PL e (EN ISO 13849-1) and SIL 3 (EN 62061)
Figure 5-9
Two-channel light grid monitoring with manual reset
PSR-ESL4/3x1/1x2/B
Order No.
2981059 with screw connection
2981062 with spring-cage connection
Technical data
–
24 V AC/DC
–
3 enabling current paths, 1 signaling current path
–
Monitored manual start or autostart
–
Basic insulation
–
Cat. 4/PLe in accordance with EN ISO 13849-1, SILCL 3 in
accordance with EN 62061
A
1
S11
S12
S22
13
23
33
A
2
S33
S34
14
24
34
41
42
(
)
(
)
(
+
)
PSR
-E
S
L
4/3x1/1x2/B
K
3
K
4
K
3
S2
M
(N)
(
L
1)
K
4
K
3
K
4
M
(
+
)
S35
(
)
L+
(
)
OSSD1 OSSD2
Li
ght
gr
i
d
type
4
Transm
i
tter
Rece
i
ver
Reset