Application manual for PSRclassic and PSRmultifunction, and the modular safety relay system
PHOENIX CONTACT
102597_en_03
5.1.1
PSR-ESL4/3x1/1x2/B up to PL c/SIL 1
Single-channel emergency stop monitoring
with manual reset
Application example
–
Single-channel emergency stop monitoring
–
Manual reset (S33, S34)
–
Stop category 0
–
Safety level of the example up to PL c (EN ISO 13849-1) and SIL 1 (EN 62061)
Figure 5-2
Single-channel emergency stop monitoring with manual reset
PSR-ESL4/3x1/1x2/B
Order No.
2981059 with screw connection
2981062 with spring-cage connection
Technical data
–
24 V AC/DC
–
3 enabling current paths, 1 signaling current path
–
Monitored manual start or autostart
–
Basic insulation
–
Stop category 0
–
Cat. 4/PLe in accordance with EN ISO 13849-1, SILCL 3 in
accordance with EN 62061
K3
S2
M
(N)
(L1)
L+
S1
A1
S
S
12
11
S22
23
13
33
41
A2
S33
S
S
34
35
24
14
34
42
( )
( )
(+)
PSR-ESL4/3x1/1x2/B
(+)
( )
( )
K3
M
Emergency
stop
Reset
Содержание 2702924