Phoenix Contact 2313669 Скачать руководство пользователя страница 1

User manual

SHDSL SERIAL permanent line modem, for 
point-to-point, line, and star structures on in-
house cables

UM EN PSI-MODEM-SHDSL/SERIAL

Order No.:

 —

Содержание 2313669

Страница 1: ...User manual SHDSL SERIAL permanent line modem for point to point line and star structures on in house cables UM EN PSI MODEM SHDSL SERIAL Order No...

Страница 2: ...AL permanent line modem for point to point line and star structures on in house cables UM EN PSI MODEM SHDSL SERIAL c00 Designation Revision Order No PSI MODEMSHDSL SERIAL 2313669 User manual Designat...

Страница 3: ...www phoenixcontact com Published by PHOENIX CONTACT GmbH Co KG Flachsmarktstra e 8 32825 Blomberg GERMANY Should you have any suggestions or recommendations for improvement of the contents and layout...

Страница 4: ...ific application in particular with regard to observ ing the applicable standards and regulations All information made available in the technical data is supplied without any accompanying guarantee wh...

Страница 5: ...ule on a DIN rail 2 2 2 1 1 Mounting on a DIN rail single device 2 2 2 1 2 Mounting with DIN rail connectors connection station 2 3 2 2 Description of the connections and LEDs 2 4 2 3 Establishing con...

Страница 6: ...I MODEMSHDSL SERIAL ii PHOENIX CONTACT 104275_en_c00 4 Optimization 4 1 4 1 Optimizing the SHDSL data rate 4 1 4 2 Increasing immunity to interference 4 2 5 Eliminating errors 5 1 5 1 Diagnostic IDs 5...

Страница 7: ...smission 2 SHDSL ports per device Up to 30 Mbps 4 wire Up to 15 3 Mbps 2 wire RS 232 interface 9 pos D SUB Transparent protocol Automatic DCE DTE switchover RS 232 up to 230 4 kbps RS 485 W2 RS 422 in...

Страница 8: ...5 m long 9 pos D SUB 9 pos D SUB socket socket PSM KA9SUB9 BB 0 5METER 2708520 0 5 m Adapter cable for connecting the IB IL RS232 and IB IL RS232 PRO Inline communication terminals to an interface co...

Страница 9: ...ormat encoding Serial asynchronous UART NRZ 7 8 data bits 1 2 stop bits 1 parity bit even odd mark space none 9 10 11 bit character length RS 485 interface Connection method Plug in and screw connecti...

Страница 10: ...nity EN 61000 6 2 Electromagnetic compatibility Conformance with EMC Directive 2004 108 EC UL USA Canada UL 508 listed in preparation Manufacturer s declaration EN 50121 4 Railway applications Electro...

Страница 11: ...ree cable types Higher data rates or longer distances can be achieved when high quality ca bles with larger diameters are used Industrial SHDSL permanent line modems from Phoenix Contact support data...

Страница 12: ...ce receives data via this connection A DTE device can be connected to a DCE device via a linear connection When connecting two devices of the same type DTE DTE or DCE DCE all cables must be crossed Th...

Страница 13: ...ase transmission reliability In addition to ensure reliable transmission the differential mode voltage between twisted wire pairs is evaluated Interference voltages in relation to ground are not taken...

Страница 14: ...terminated at both ends by a ter mination resistor 100 200 ohms The individual devices can be located away from the bus cable using branch lines The length of the branch lines depends on the data rate...

Страница 15: ...general software handshake for all three interfaces This is therefore not supported either You can implement a point to point connection in which full and half duplex interfaces are used e g RS 485 a...

Страница 16: ...alf duplex mode RS 232 and RS 422 interfaces are usually designed for a point to point connection and not a line structure In mixed operation with an RS 232 device and an RS 422 or RS 485 device hardw...

Страница 17: ...RS 232 RS 422 and RS 485 This is therefore not supported either You can implement a line structure in which full and half duplex interfaces are used e g RS 485 and RS 232 RS 422 In this case however...

Страница 18: ...s In the example you need to create two line structures each consisting of three devices Figure 1 9 Example for a star structure RS 485 interface on all devices In principle a star structure via the D...

Страница 19: ...individually via the PSI CONF configuration software We recommend beginning with the critical line These for example are long lines with many devices and small cable diameters Another example Figure...

Страница 20: ...led together via a head station In both examples above devices A5 B2 and C3 are connected via a DIN rail connector T BUS Figure 1 12 Examples for RS 485 head stations Key Segments For a head station w...

Страница 21: ...mixed structure RS 485 interface The SHDSL modems are configured via the software as a line structure with three devices for example When using a DIN rail connector all devices must use the RS 485 int...

Страница 22: ...n_c00 1 6 6 Branches and branch lines Branches and branch lines are not supported by the SHDSL modem SHDSL only supports point to point communication and not multipoint communication Figure 1 15 Branc...

Страница 23: ...ntrol 8N1 8 data bits no parity 1 stop bit RS 485 deactivated RS 422 deactivated Digital switching outputs Tips for easy startup Point to point connection of two devices Connect DSL port A of device 1...

Страница 24: ...by the housing cover carefully push the device towards the mount ing surface Once the snap on foot has been snapped onto the DIN rail check that it is fixed secure ly Removal Use a suitable screwdrive...

Страница 25: ...igure 2 2 Mounting and removal connection station Push the DIN rail connectors together A and insert them into the DIN rail B C Place the device onto the DIN rail from above so that the upper housing...

Страница 26: ...nsmit data at D SUB or COMBICON 18 RD green Receive SERIAL data OFF No data received at D SUB or COMBICON ON Receive data at D SUB or COMBICON 19 DG yellow Diagnostics OFF No serious errors Flashing 1...

Страница 27: ...o start up to ground and to mark devices systems and equipment according to the standards of safety technology In addition these persons must be familiar with all warning instructions and maintenance...

Страница 28: ...ort A to DSL port B on the same device DSL loop In order to make data transmission less susceptible to interference we recommend using shielded twisted pair cables You can use star quad twisted cables...

Страница 29: ...The 4 wire connection can be used for line redundant operation or to increase the speed In the case of star quad twisted cables use the individual wires on the opposite side 1a 1b or 2a 2b to avoid c...

Страница 30: ...ttings Connection Connect the cable to the corresponding screw terminal block In order for the switching outputs DO DIO to function the modem must be supplied with voltage via the COMBICON plug in con...

Страница 31: ...to devices which meet the requirements of EN 60950 Safety of information technology equipment Interface basics RS 232 See RS 232 on page 1 6 RS 422 See RS 422 on page 1 7 RS 485 W2 See RS 485 W2 on p...

Страница 32: ...matic DCE DTE detection must be disabled on one of the devices If the third party device switches between DCE and DTE during operation e g be cause a switch has been actuated the modem does not detect...

Страница 33: ...ot electrically isolated from the potential of the supply voltage Table 2 2 Assignment of the RS 485 RS 422 interface COMBICON Contact RS 485 W2 RS 422 Assignment 1 R N 2 R P 3 D A T N 4 D B T P 5 GND...

Страница 34: ...LED flashes at 1 Hz in this case SHDSL operation is not possible To connect the modem to a computer use the CABLE USB MINI USB 3 0M cable Order No 2986135 Connect the mini USB plug type B to the mode...

Страница 35: ...gure 2 9 Connecting the supply voltage Using the system power supply unit optional Connect the MINI SYS PS 100 240AC 24DC 1 5 system power supply unit Order No 2866983 using two DIN rail connectors Or...

Страница 36: ...Freestanding 40 mm spacing 20 C 60 C Connected in series low power dissipation of modules connected in series 20 C 55 C Connected in series without restrictions 20 C 50 C Operation other modules supp...

Страница 37: ...RNING Explosion hazard Disconnect the block power supply before Snapping it on or disconnecting it Connecting or disconnecting cables WARNING Explosion hazard The mini USB configuration interface may...

Страница 38: ...PSI MODEMSHDSL SERIAL 2 16 PHOENIX CONTACT 104275_en_c00...

Страница 39: ...e handshake etc Changes to the configuration of digital switching outputs Changes to the DSL transmission speed 4 wire operation 64 kbps 30 Mbps manual setting of the data rate 384 kbps 11 392 Mbps au...

Страница 40: ...from the CD ROM supplied When the CD ROM is inserted the index html file will launch automatically in your browser If this file does not open double click on it to start it Select a language English G...

Страница 41: ...red language To do this click on Language Sprache in the menu at the top left and select English Englisch German Deutsch or Chinese Simplified 3 2 2 Selecting the device Next select the device that yo...

Страница 42: ...USB cable Configuration is performed directly The software switches to online mode Configuration file You can create a new project or open an existing project A new window appears when you click on Co...

Страница 43: ...how many devices are to be connected 3 to 255 devices supported In the case of the point to point wizard two devices are connected to each other Select a file name and storage location for the config...

Страница 44: ...rans mission speed taking a reserve of 3 dB into account in the range of 192 5696 kbps per channel The automatically determined data rate remains fixed until an SHDSL connec tion abort The SHDSL data...

Страница 45: ...TIdleMin parameter relates to the minimum time that must elapse between two successive frames A certain amount of time must elapse between two frames to prevent the concatenation of multiple frames O...

Страница 46: ...mation on DCE DTE switchover please refer to RS 232 interface on page 2 11 Termination RS 485 W2 only the 2 wire bus cable must be terminated at both ends by a termination resistor 100 200 ohms When T...

Страница 47: ...see Event log on page 3 13 The diagnostic LED remains lit until it is reset You can specify a fixed time interval for reset e g after 2 minutes or reset the LED manually Manual reset is performed usin...

Страница 48: ...device connected via USB After successful transfer a green bar appears displaying Transferred and the serial number of the device A USB symbol also appears Select the next device and connect it via t...

Страница 49: ...s This function is only available in online mode The device is supplied with the following configuration Line operation DSL Automatic data rate detection in the range from 192 kbps to 5 696 Mbps per c...

Страница 50: ...al No The serial number is unique for each device It can be used to assign a device and is printed on the device Device name This is the name of the device that you assigned during confi guration Oper...

Страница 51: ...A few errors at the interface This can result in significant errors for example A configuration error is probably pres ent e g due to an incorrect data rate or a short circuit on the data cable 8 Many...

Страница 52: ...n your system are identical de crease the serial data rate of all serial interfaces or reduce the data load If RS 232 or RS 422 interfaces are used in a line struc ture make sure that they are only op...

Страница 53: ...Possible values include Error Warning or Information Time based on PC clock Date and time of the event based on the PC clock ID The event ID The IDs of diagnostic messages are described under Diagnos...

Страница 54: ...ratio the higher the transmission quality The signal to noise ratio mainly depends on the cable attenu ation and the interference signals that influence the cable e g from adjacent cables Port A B Li...

Страница 55: ...dicates the status of the serial connection via the RS 232 in terface Diagnostics Value log Transfer Open file and write to device or Read configura tion and save to file This function is only availab...

Страница 56: ...used to clearly identify the device type Serial No The serial number is unique for each device It can be used to assign a device and is printed on the device Hardware version The hardware version numb...

Страница 57: ...sure that the DSL data rate is set to automatic see Step 3 DSL line configuration on page 3 6 Using the diagnostic function display the actual SHDSL data rate on the line see Di agnostic overview on p...

Страница 58: ...serial data rate that your application permits The lower the serial data rate the better the immunity to interference Example formula for character based transmission Calculate new SHDSL data rate fo...

Страница 59: ...or B errors Check DSL installation Check whether the wire pair is connected correct ly twisted pair star quad stranding Check cables for line in terruption short circuit If available connect cable sh...

Страница 60: ...ca ble 1 Check the cable resistance between SHDSL_A and SHDSL_B 2 Check whether the wire pairs are connected correctly twist ed pair star quad stranding 3 Check cables for line interrup tion short cir...

Страница 61: ...ty data bits 7 or 8 bits stop bits data rate 022 Data overload on the SHDSL line ERR LED and DIAG LED on At least temporarily the transmis sion capacity of the SHDSL line is not large enough Data can...

Страница 62: ...data load If RS 232 or RS 422 interfaces are used in a line structure ensure that they work only in half duplex mode 028 Expected SHDSL data rate could not be reached ERR LED and DIAG LED on While th...

Страница 63: ...too high The warning is relevant if there are frequent link aborts see event no 5 090 Link state changed from Link established to Link is down 1 Connector was unplugged 2 DSL path was interrupted 3 Po...

Страница 64: ...the serial data rate may be configured wrong there may be a short circuit on the serial data line a driver of a device connected to the serial port may be de fective Check the device configurati on se...

Страница 65: ...ing 1 Hz The specified DSL port found a link partner 176 Link state changed to Initializing LINK LED blink ing 2 Hz The specified DSL port changes to the initialization phase 177 Link established LINK...

Страница 66: ...partner 191 reserved 192 reserved 193 reserved 194 reserved 195 reserved 196 reserved 197 reserved 198 A DTE device is con nected to the RS 232 in terface There is a device connected via a 1 1 cable...

Страница 67: ...no more data loss was detected 206 Data is received from the SHDSL port Data is received from the specified SHDSL port and sent to the serial interface For at least one minute this has not been the ca...

Страница 68: ...PSI MODEMSHDSL SERIAL 5 10 PHOENIX CONTACT 104275_en_c00...

Отзывы: