![Phoenix Contact 1624130 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/phoenix-contact/1624130/1624130_user-manual_1551407034.webp)
EV
-
PLCC
-
AC1
-
DC1
34 / 74
PHOENIX CONTACT
107068_en_06
Figure 3
-
19
Connection example 2: charging connector with charging contactor
3.9.1.1
Relay output, charging contactor (AC charging)
A relay output is available to connect to an external charging contactor for AC charging pro
-
cesses.
Figure 3
-
20
Terminal point assignment of relay output, charging contactor
Table 3
-
9
Terminal point assignment of relay output, charging contactor (AC
charging)
Terminal point
Assignment Description
1.1
C1
Relay output, charging contactor
Connects the mains voltage to the vehicle via
an external charging contactor if status C or D
has been reached and the corresponding en
-
able requirements have been fulfilled.
1.2
C2
X6
X7
1
2
3
4
5
6
7
8
9
1
2
N
PE
L, L1-L3
30 V
1
3
2
6
1A
2A
7
8
CP
4
5
EV
CH
A
R
GE
CON
T
RO
L
X2.2
X3
X4
RS232
RS485
RS485
X5
COM
X7
AC Charging
X8
X9
SD CARD
Digital OUT
X11
Digital IN
X10
SIM
ANT
UL
UM
US
FR
FF
E
RS232-1
RS232-2
RS485-1
RS485-2
CAN
GSM St.
GSM TR.
Error
Plug
Charge
PLC
Error
Plug
Charge
1.1