Installation
4031_en_C
PHOENIX CONTACT
13/24
3.2.2
Serial communication
Two D-SUB 9 connectors (see
) can be configured to communicate on the
RS
-
232, RS
-
422, or RS
-
485 physical layer.
The BL2 PPC 1201-4/… is capable of the following communication parameters:
The function of the pins in the D-SUB 9 connector varies with the different configuration
settings.
Table 3
-
3
RS-232/422/485 communication settings
Data bits
Parity
Stop bits
RS-232
7/8
None/Even/Odd
1/2
RS-422/485 Autotoggle RTS
8
None/Even/Odd
1/2
RS-422/485 Manual RTS
7/8
None/Even/Odd
1/2
The table shows the capabilities of the IPC. Configuration of parameters to communicate
with a specific device is typically part of the software tool performing the communication.
Table 3
-
4
D-SUB 9 pinout
D-SUB 9 pin
RS-232
RS-422
RS-485
1
DCD
TXD-
TXD-/RXD-
2
RXD
TXD+
TXD+/RXD+
3
TXD
RXD+
–
4
DTR
RXD-
–
5
GND
GND
GND
6
DSR
–
–
7
RTS
–
–
8
CTS
–
–
9
Ring indicator
–
–
Содержание 1274012
Страница 1: ...User manual UM EN BL2 PPC 1200 Basicline 2 PPC 1200 industrial PC...
Страница 4: ...BL2 PPC 1201 4 4 24 PHOENIX CONTACT 4031_en_C...
Страница 8: ...BL2 PPC 1201 4 8 24 PHOENIX CONTACT 4031_en_C...
Страница 20: ...BL2 PPC 1200 20 24 PHOENIX CONTACT 4031_en_C...
Страница 22: ...BL2 PPC 1200 22 24 PHOENIX CONTACT 4031_en_C...