BL2 PPC 1201-4/…
10/24
PHOENIX CONTACT
4031_en_C
2. Remove the paper seal (1) from the sticky side of the gasket (2) and apply it to the back
side of the bezel (3).
Figure 3
-
2
Gasket installation
3. Insert the BL2 PPC 1201-4/… through the opening.
4. Insert the screws (1) through the clamps (2).
Figure 3
-
3
Panel-mounting clamps
5. From the rear of the enclosure, place a clamp in each slot (3) and slide away from the
enclosure panel.
6. Using an alternating pattern, turn each screw clockwise until the BL2 PPC 1201-4/… is
secured in the enclosure panel.
7. Torque each clamp screw to 0.88 Nm.
USB2
.0
PO
WER
1
2
3
1
2
3
Содержание 1274012
Страница 1: ...User manual UM EN BL2 PPC 1200 Basicline 2 PPC 1200 industrial PC...
Страница 4: ...BL2 PPC 1201 4 4 24 PHOENIX CONTACT 4031_en_C...
Страница 8: ...BL2 PPC 1201 4 8 24 PHOENIX CONTACT 4031_en_C...
Страница 20: ...BL2 PPC 1200 20 24 PHOENIX CONTACT 4031_en_C...
Страница 22: ...BL2 PPC 1200 22 24 PHOENIX CONTACT 4031_en_C...