BGP221/231

TownTune

Central Post-Top

1/12

 583 443000020784_A
© 01 / 2019, Signify Holding. All rights reserved

Photobiological Risk
Luminaire Surge Protection
Luminaire Surge Protection with SPD *optional

RG1 (valid for Neutral and Warm White)
DM/CM  6/8 kV (C-I/C-II)
DM/CM  10/10 kV (C-I) - 10/8 kV (C-II) - 10/10 kV (C-II) (optional ground for installer)

Printed in Spain
Data subject to change without notice
Keep for future reference: www.philips.com/lighting

740

LED14

12

10

1400

0,042

6,8kg*

LED16

12

11

1600

LED18

12

12

1800

LED20

12

13

2000

LED22

12

14

2200

LED24

12

16

2400

LED27

12

18

2700

LED30

12

20

3000

LED35

12

24

3500

LED39

12

27

3900

LED45

20

29

4500

LED50

20

32

5000

LED55

20

35

5600

LED59

20

38

6000

LED64

20

42

6400

LED69

40

41

7000

LED74

40

44

7400

LED79

40

47

8000

LED84

40

50

8400

LED90

40

53

9000

LED94

40

56

9400

LED100

40

60

10000

BDP260/261/262/263

Standard luminaire housing BDP260 is IK10. Added accessories are rated at IK08.
As accessories are not a structural part of the luminaire housing, the IK rating for the luminaire housing remains IK10.

Содержание TownTune BDP260

Страница 1: ...ips com lighting 740 LED14 12 10 1400 0 042 6 8kg LED16 12 11 1600 LED18 12 12 1800 LED20 12 13 2000 LED22 12 14 2200 LED24 12 16 2400 LED27 12 18 2700 LED30 12 20 3000 LED35 12 24 3500 LED39 12 27 3900 LED45 20 29 4500 LED50 20 32 5000 LED55 20 35 5600 LED59 20 38 6000 LED64 20 42 6400 LED69 40 41 7000 LED74 40 44 7400 LED79 40 47 8000 LED84 40 50 8400 LED90 40 53 9000 LED94 40 56 9400 LED100 40 ...

Страница 2: ...ces Weight of decorative ring 0 6 kg Weight of top accessory cone 1 1 kg Weight of top accessory dome 0 8 kg WARNING This luminaire must be installed only by qualified personnel If the external flexible cable or cord of this luminaire is damaged it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard The light source contai...

Страница 3: ...ind surface 0 066m2 SCx 0 036m2 TOWNTUNE CENTRAL POST TOP DTD Wind surface 0 082m2 SCx 0 039m2 TOWNTUNE CENTRAL POST TOP DR DTD Wind surface 0 11m2 SCx 0 057m2 TOWNTUNE CENTRAL POST TOP DTC Wind surface 0 11m2 SCx 0 052m2 TOWNTUNE CENTRAL POST TOP DR DTC Wind surface 0 13m2 SCx 0 071m2 3 12 ...

Страница 4: ...OPEN CLOSE MOUNTING CABLE LC05 VERSION STANDARD VERSION Allowed cable range Ø5 Ø8 7 Ø12 mm 4 12 ...

Страница 5: ...DECORATIVE RING FIXATION SPIGOT FIXATION 5 12 ...

Страница 6: ...1 MOUNTING OF PHOTOCELLS Citytouch OLC COM SR 2 Citytouch OLC NEMA SR 6 12 ...

Страница 7: ...for installer GROUND 1 4 2 5 PSD CONNECTION Class I Class II 3 LINE Brown 1 LINE Brown N NEUTRAL Blue 2 NEUTRAL Blue GROUND Yellow Green 3 Optional for installer GROUND 1 DALI 4 DALI 2 DALI 5 DALI PSR CONNECTION Class I Class II 3 LINE Brown 1 LINE Brown N NEUTRAL Blue 2 NEUTRAL Blue GROUND Yellow Green 3 Optional for installer GROUND 1 4 2 Lineswitch 5 Lineswicth 7 12 ...

Страница 8: ...urge Protection PSU PSA PSDD CONNECTION with Surge Protection Class II L LINE Brown L LINE Brown X Optional for installer GROUND X Optional for installe GROUND N NEUTRAL Blue N NEUTRAL Blue DA DALI DA DALI PSR CONNECTION Class I Class II L LINE Brown L LINE Brown GROUND Yellow Green X Optional for installer GROUND N NEUTRAL Blue N NEUTRAL Blue Lc LineSwich Lc LineSwich PHOTOCELL CONNECTION Class I...

Страница 9: ...alkaline and or acetous cleaning substances Make sure that cleaning substance is fully removed by rinsing with clean water Full Prog Coded Mains System Ready The maximum number of luminaires with driver 40W to be connected in MCB 16A TYPE B mains impedance 200 mΩ 400 µH 20 20 21 Inrush current lpeak 22 A 22 A 21 A Inrush current Twidth 290 µs 290 µs 300 µs input voltaje 230V input voltaje 230V mea...

Страница 10: ...hooting Problembehebung Resolución de problemas Dépannage Spare parts list Ersatzteilliste Listado de repuestos Liste des pièces de rechange Driver re programming Treiber Neuprogrammierung Reprogramación del driver Reprogrammation du Driver Want to know more about Service tag Go to www philips com servicetag 10 KV PROTECTION 10kV extra surge protection SRG10 is ensuring Differential mode protectio...

Страница 11: ...ing philips com main prof NL Hierbij verklaar ik dat het type radioapparatuur conform is met Richtlijn 2014 53 EU De volledige tekst van de EU conformiteitsverklaring kan worden geraadpleegd op het volgende internetadres http www lighting philips com main prof PL niniejszym oświadcza że typ urządzenia radiowego jest zgodny z dyrektywą 2014 53 UE Pełny tekst deklaracji zgodności UE jest dostępny po...

Страница 12: ... the information included herein is given and any liability for any action in reliance thereon is disclaimed The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N V All other trademarks are owned by Signify Holding or their respec...

Отзывы: