GETTING STARTED

sPDS-60ca 24V is a compact power/data supply for indoor installations. 

sPDS-60ca 24V provides power and data to  24 VDC Chromasic®-driven 

product lines, and is available for DMX and Ethernet control options.
The "s" type of power supply provides additional features, such as base 

address and grouping of light fixture addresses, without the need for 

external components.
This guide contains important information on installing and using your new 

sPDS-60ca 24V. Please read it carefully and save it for future reference.

Included In This Box

•  Power/data supply
• US or EU/UK Grounded IEC Cord Set
• RJ45 Terminator
• 3 clamp-on EMI Suppression Cores (1-Black, 2-White)
• User Guide

Additional Items Needed

•  Mounting hardware – 4 flat head screws M3.5 or #6

Scope of this Document

The scope of this document is to explain the steps necessary to install sPDS-

60ca 24V for DMX and Ethernet control to assure peak performance. Its 

intended use is for reference only, by persons who are fully qualified. This 

document should never be considered a substitute for any provisions of a 

regulation or state and/or local code.

Identification and Warnings of Safety Hazards

In accordance with ANSI Z535.4-2002, the following system identifies the 

severity of the hazards associated with the products:

danger

”  Imminently hazardous situation which, if not avoided, will result in 

death or serious injury.

warning

”  Potentially hazardous situation which, if not avoided, could result in 

death or serious injury.

caution

”  Potentially hazardous situation which, if not avoided, may result in 

minor or moderate injury or property damage. Also used to alert 

against unsafe practices.

ignoring

 

a

 

hazard

 

will

 

void

 

any

 

warranty

warning

: Ensure that power is disconnected before installing, wiring, or 

servicing the sPDS-60ca 24V power supply.  

warning

: The sPDS-60ca 24V power supply must be installed by a 

qualified professional in accordance with NEC and relevant local codes. 

warning

: Do not attempt to install or use sPDS-60ca 24V until you read 

and understand the installation instructions and safety labels.  

warning

: The sPDS-60ca 24V power supply must be installed without 

ventilation openings facing down.

warning

: Do not use sPDS-60ca 24V if power cables are damaged.  

warning

: This equipment has been tested and found to comply with the 

limits for a Class A digital device, pursuant to part 15 of the FCC Rules. 

This equipment generates, uses, and can radiate radio frequency energy 

and, if not installed and used in accordance with the instruction manual, 

may cause harmful interference to radio communications. Operation of this 

equipment in a residential area is likely to cause harmful interference in 

which case the user will be required to take adequate measures. 

caution

: Ensure that sPDS-60ca 24V is securely attached, properly 

mounted, and free of excessive vibration. 

caution

: sPDS-60ca 24V must be installed in a location that allows air to 

move freely. Packing insulation around the housing or mounting in a sealed 

location that raises ambient temperature above 122˚ F (50˚ C) will result in 

property damage and will void the warranty. 

caution

: Do not hot swap. Ensure the power supply is off before 

connecting or disconnecting fixtures. 

caution

: Do not modify or alter sPDS-60ca 24V. 

note

:

 

The instructions and precautions set forth in this installation guide 

are not necessarily all-inclusive or relevant to all applications as Philips 

cannot anticipate all conceivable or unique situations.

Owner/User Responsibilities

It is the responsibility of the contractor, installer, purchaser, owner, and 

user to install, maintain, and operate sPDS-60ca 24V in such a manner as 

to comply with all state and local laws, ordinances, regulations, and the 

American National Standards Institute Safety Code.

note

:

 sPDS-60ca 24V is shipped with a US IEC power cable. For 

international customers, use a country-specific IEC cable meeting the 

following specifications: 3-conductor, 18 AWG (1.00mm2), HAR rating for 

Europe, and JET rating for Japan. (Hard Service Type ST or equivalent.)

note

:

 Ensure the IEC inlet plug fits in the supplied lock. The lock may not 

accommodate all plug styles. 

INSTALLING sPDS-60ca 24V

sPDS-60ca 24V must be installed by a qualified electrician in accordance 

with NEC and relevant local codes for power supplies. A power 

screwdriver is recommended for mounting the unit.

Mounting the Housing

•  Select the location to mount the housing, keeping sPDS-60ca 24V within 

the maximum distance specified for your fixture. Refer to your fixture 

user guide for the cable run information.

NOTE

Ensure that there is adequate space to make all connections to 

the front and rear of the unit.

•  Mount the housing to a flat surface using four M3.5 or #6 flat head 

screws suitable for the mounting surface. Mounting slots are located on 

each end of the housing. (See Fig. 1.)

NOTE

Do not overtighten the mounting screws.

WIRING sPDS-60ca 24V

After mounting the power/data supply, you are ready to connect power, 

lights, and data to sPDS-60ca 24V.

Connecting Lights to sPDS-60ca 24V 

• Install white clamp-on EMI Suppression Core on fixture leader cable. 

Follow instructions in figure 2a for method of installation. 

• Plug the leader cable connector into a power output receptacle on 

the front of sPDS-60ca 24V. Power outputs are labeled Out 1 and Out 

2. (See Fig. 2b.) 

note

:

 When using one light run per sPDS-60ca 24V, use 

Output 1. 

• Refer to Table 1 to determine maximum number of fixtures supported. Refer to 

the Installation Instructions of the fixture for specific wiring requirements. 

Table 1: Maximum Fixtures Supported per sPDS-60ca 24V

Fixture

Maximum Quantity per 

sPDS-60ca 24V

Maximum per Power Port

iColor Cove EC, 12 in

30

15 

iColor Cove EC, 6 in

30

15

iColor Cove QLX, 12 in

20

10

iColor Cove QLX, 6 in

30

15

eW Flex Micro

120 nodes

1

eW Flex Compact

60 nodes

1

Connecting DMX Data to sPDS-60ca 24V

sPDS-60ca 24V receives DMX data from, and can be controlled by, Philips 

full line of DMX512 controllers or any third party DMX512 controller. 
•   Plug the data RJ45 connector from the controller into the DMX IN port. 

•  To daisy-chain DMX data to another sPDS-60ca 24V, connect a CAT 5 

cable with RJ45 connectors between the DMX OUT port of the first unit 

and the DMX IN port of the next unit. Plug a terminator into the DMX 

OUT port of the last power supply in a data chain. (See Fig. 3.)

Connecting Ethernet Data to sPDS-60ca 24V

sPDS-60ca 24V receives Ethernet data from Light System Manager (LSM) 

or Video System Manager (VSM). LSM consists of Light System Composer 

software and Light System Engine hardware, and VSM consists of Video 

System Manager software and Video System Engine hardware. A dedicated 

network and one or more Ethernet switches are required for your 

installation. (See Fig. 4.) Refer to the LSM User Guide or VSM User Guide 

for setup and configuration information. 

• Connect the CAT-5e data cable, with RJ45 connectors on both ends, to 

the Ethernet switch and to the ENET IN port on the sPDS-60ca 24V 

power/data supply. 

note

: End-run Ethernet data to each sPDS-60ca 24V in an installation. 

Ethernet cannot be daisy chained. (See Fig. 4.) 

Connecting Power to sPDS-60ca 24V

• Install black clamp-on EMI Suppression Core on IEC power cable. Follow 

illustrations in Figure 5a for method of installation.

• Connect the IEC power cable to the back of sPDS-60ca 24V. Plug the IEC 

power cable into a standard 100 – 240 VAC outlet. Tighten the screw to 

secure the clamp. (See Fig. 5b.)

8.31 in

(211 mm)

2.25 in

(57 mm)

Fig. 1

OUT 

1

OUT 

2

ENET IN

DMX IN

DMX OU

T

AL

T

DA

TA

Fig. 2b

To Lights

OUT 

1

OUT 

2

ENET IN

DMX IN

DMX OU

T

AL

T

DA

TA

OUT 

1

OUT 

2

ENET IN

DMX IN

DMX OU

T

AL

T

DA

TA

DMX IN

DMX OUT

DMX IN

To Lights

Terminator

Philips

Controller

Fig. 3

Ethernet

Switch

PC*

* PC used for show authoring and show control. 

sPDS-60ca 24V

To Lights

OUT 

1

OUT 

2

ENET I

N

DMX IN

DMX OU

T

AL

T

DA

TA

OUT 

1

OUT 

2

ENET I

N

DMX IN

DMX OU

T

AL

T

DA

TA

sPDS-60ca 24V

To Lights

100 – 240 VAC

100 – 240 VAC

Ethernet IN 

(CAT 5e)

Ethernet IN 

(CAT 5e)

Video

System

Engine

Light

System

Engine

or

Fig. 4

DMX/Ethernet Control

Philips Solid-State Lighting Solutions, Inc.

3 Burlington Woods Drive

Burlington, Massachusetts 01803 USA

Tel 888.Full.RGB

Tel 617.423.9999

Fax 617.423.9998

www.colorkinetics.com

ITEM # 109-000021-04 

(DMX/Ethernet, N.A. Cord Set)

ITEM # 109-000021-05 

(DMX/Ethernet, EU/UK Cord Set)

Copyright © 2016 Philips Solid-State Lighting Solutions, Inc.  All rights reserved.

Chromacore, Chromasic, CK, the CK logo, Color Kinetics, the Color Kinetics logo, 

ColorBlast, ColorBlaze, ColorBurst, ColorGraze, ColorPlay, ColorReach, iW Reach, 

eW Reach, DIMand, EssentialWhite, eW, iColor,  iColor Cove, IntelliWhite, iW, iPlayer, 

Optibin, and Powercore are either registered trademarks or trademarks of Philips 

Solid-State Lighting Solutions, Inc. in the United States and/or other countries. All other 

brand or product names are trademarks or registered trademarks of their respective 

owners. Due to continuous improvements and innovations, specifications may change 

without notice.

PUB-000148-00 Rev 05

sPDS-60ca 24V

i n s t a l l a t i o n

 

i n s t r u c t i o n s

Fig. 2a

6 in (152 mm)

6 in (152 mm)

Fig. 5a

Отзывы: