background image

Service Manual

Philips Domestic Appliances and Personal Care

Published by Philips Domestic Appliances and Personal Care 

Printed in the Netherlands 

© Copyright reserved 

Subject to modification

 

 

Coffee Maker Senseo

HD7824/50

/B

06/09

PRODUCT INFORMATION

-  This product meets the requirements regarding 

interference suppression on radio and TV.

-  After the product has been repaired, it should function 

properly and has to meet the safety requirements as 
officially laid down at this moment.

TECHNICAL INFORMATION

-  Voltage 

:  220 - 240 V

-  Frequency 

:  50 - 60 Hz

- Power consumption 

: 1450 W

- Standby power 

: 1.2 W

-  Contents reservoir 

:  1200 cc

- Colour setting 

: Chrome Silver

- Sap coding 

: HD7824/50/B

CONTROL

PCB

L

N

Boiler

Pump M

Fuse

Temp.
Sensor

Water level
sensor S1

Water level

sensor S2

 Push buttons

Fuse

Содержание Senseo HD7824/50/B

Страница 1: ...regarding interference suppression on radio and TV After the product has been repaired it should function properly and has to meet the safety requirements as officially laid down at this moment TECHNICAL INFORMATION Voltage 220 240 V Frequency 50 60 Hz Power consumption 1450 W Standby power 1 2 W Contents reservoir 1200 cc Colour setting Chrome Silver Sap coding HD7824 50 B CONTROL PCB L N Boiler ...

Страница 2: ...y pushing the main switch LED will turn off 11 Turn appliance on again and brew one cup measure the volume In case the volume is not within specification repeat steps 6 11 12 End DISASSEMBLY AND RE ASSEMBLY ADVISE To remove the back cover follow below steps Remove Screw A see exploded view Remove valve outlet Start at the upper side of the back cover and stick a screwdriver into the 2 snap locks p...

Страница 3: ...ions it is handy to restore the Boiler_empty_ flag again to production default in the Eeprom Bringing the Senseo back into production status has the benefit the flush routine will be activated automatically when installed by the consumer see topic Automatic filling procedure To SET the Boiler_empty_flag can be done by Keep the 1 cup button pressed while plugging in the power cord of the appliance ...

Страница 4: ...HD7824 50 B 4 5 EXPLODEDVIEW B B X 4 3 5 1 9 10 12 11 8 2 7 6 ...

Страница 5: ...HD7824 50 B 5 5 EXPLODEDVIEW X A 18 19 20 16 17 21 22 23 24 25 15 14 13 ...

Отзывы: