background image

Version 5: September 2010 

 

 

Shutter System: 

 
The  shutters  are  used  to  mask  a  portion  of  the  beam  shaping  it,  masking  light  off  scenery,  curtains,  etc.  Your  Acclaim 
Zoomspot  features  an  off-centre  shutter  blade  system  developed  by  Philips  Selecon.  The  larger  section  of  the  unequal 
blade can be moved significantly around the axis of the beam providing a very wide range of masking angles. 
 
Remember the optical system inverts all images at the gate, i.e. the top shutter on the luminaire masks the bottom part of 
the light beam. 
 
 

Pattern Projection: 

 
The rotatable pattern holder comprises the holder and a spring clip to hold the pattern flat against the holder. The holder 
can be rotated in the slot to align the image as required on the stage. 

NOTE:

 

The Acclaim range uses „M‟ size patterns, with an image diameter of 50mm / 2”. 

The accessory mounting slot will also house - 

 

An adjustable Iris 

 

A motorised pattern holder eg: Rosco/ DHA RTR008 

To  mount  the  accessory  in  the  aperture  slot  ensure  the  pattern  spring  clip  is  facing  to  the 
front of the luminaire and slide into the slots formed as part of the shutter plates. 
 

NOTE: Do not run the luminaire with all the shutters closed, as this may cause the luminaire to over-heat. 

 
 

Interchangeable Lens Trays: 

 
The variable lens tray assemblies are interchangeable so you can change an 18º-34º luminaire to 
a 24º-44º. Open the tray, with the tray hanging down, lift up and out to free the hinge. 

 
 

Cleaning: 

 

Reflector - wipe with a soft cloth to remove accumulated dust. 
Lens - the assembly can be removed out of the luminaire, clean with a soft cloth. To remove baked on dust use a window 
cleaner. 
 
 

Accessories: 

 
Suspension Hookclamp (Order Code 20HC)   

Adjustable Iris (Order Code 15ACIRIS) 

 

 

 

Lens Safety Mesh (Order Code 15ACSM) 

 

24º-44º lens tray (Order Code 15ACLTW) 

 

 

 

Rotatable pattern holder (Order Code 15ACGH) 

18º-34º lens tray (Order Code 15ACLTS)  

 

 

 

Colour Frame 

– each luminaire is supplied with a 125mm square colour filter holder. Additional colour frames are available 

(Order Code 20CFMF) 

 

 

Safety and Maintenance: 

 
Philips  Selecon  has  manufactured  this  luminaire  in  accordance  with  recognised  best  practices  to  recommended 
international safety standards. It is your responsibility to maintain this luminaire in good and safe working condition. 

 

Repairs should only be carried out by suitably qualified persons. Do not operate the luminaire with cracked lens, damaged 
cable, etc. Consult your Philips Selecon distributor for assistance. Only replace with damaged parts with authorised Philips 
Selecon spares. 

N.B.

  Luminaire  cables 

–  your  Philips  Selecon  luminaire  is  fitted  with  special  heat  resistant  flexible  cable,  replace  with 

genuine  Philips  Selecon  spare  part  cable  kit  only 

–  refer  to  your  Philips  Selecon  distributor.  (Replacement  cables  are 

supplied  complete  with  necessary  terminal 
connectors). 
 
Cable conductor colour codes:  

  

 

ONLY FIT A PLUG IF YOU ARE A SUITABLY 
QUALIFIED TECHNICIAN 

 

 

 

Содержание Selecon Acclaim

Страница 1: ...tirely at your risk Read this manual from cover to cover before attempting installation Do not attempt installation unless you are suitably qualified If you do not understand a point in this manual don t guess Don t take short cuts If in doubt stop Contact Philips Selecon or one of its authorised distributors for advice Don t be afraid to ask for help Table of Contents Important 2 Safety Warnings ...

Страница 2: ...rty Philips Selecon used all due care in preparing this manual However Philips Selecon accepts no liability for errors or omissions Philips Selecon reserves the right to change the specifications of its luminaires or the information in this manual without necessarily giving its customers notice thereof Installation operation and maintenance are entirely at the customer s risk Philips Selecon lumin...

Страница 3: ...t Pass the set screw through the yoke hole from the inside put on a washer then the hook clamp another washer and then tighten the nut If you are not using the set screw washers and nut please dispose of them responsibly To mount on a telescopic stand Reverse the yoke under the luminaire and bolt the stand s spigot onto the set screw Yoke Pivot Adjustment The yoke on the Acclaim range can be posit...

Страница 4: ...4 8m away and focus light to narrow angle front lens forward rear lens back To obtain sharp focus adjusts rear lens only Adjust lamp peak flat knob towards back for flattest field and forward for peaked position Reconnect the luminaire to the power supply and bring up on the dimmer Focusing your Zoomspot The variable beam of your Acclaim Zoomspot is altered by adjusting the front and rear lens in ...

Страница 5: ... 44º Open the tray with the tray hanging down lift up and out to free the hinge Cleaning Reflector wipe with a soft cloth to remove accumulated dust Lens the assembly can be removed out of the luminaire clean with a soft cloth To remove baked on dust use a window cleaner Accessories Suspension Hookclamp Order Code 20HC Adjustable Iris Order Code 15ACIRIS Lens Safety Mesh Order Code 15ACSM 24º 44º ...

Страница 6: ... indirect incidental special or consequential costs or damages including dismantling and re installation costs loss of operations or profits to the maximum extent permitted by law Philips Selecon accepts no liability for personal injury or property damage resulting from failure to heed relevant operating and safety procedures specified by Philips Selecon or imposed by law This is an express warran...

Страница 7: ...Version 5 September 2010 7 ...

Отзывы: