Shutter System:
The shutters are used to mask a portion of the beam shaping it, masking light off scenery, curtains, etc. Your Acclaim
Zoomspot features an off-centre shutter blade system developed by Philips Selecon. The larger section of the unequal
blade can be moved significantly around the axis of the beam providing a very wide range of masking angles.
Remember the optical system inverts all images at the gate, i.e. the top shutter on the luminaire masks the bottom part of
the light beam.
Pattern Projection:
The rotatable pattern holder comprises the holder and a spring clip to hold the pattern flat against the holder. The holder
can be rotated in the slot to align the image as required on the stage.
NOTE:
The Acclaim range uses „M‟ size patterns, with an image diameter of 50mm / 2”.
The accessory mounting slot will also house -
An adjustable Iris
A motorised pattern holder eg: Rosco/ DHA RTR008
To mount the accessory in the aperture slot ensure the pattern spring clip is facing to the
front of the luminaire and slide into the slots formed as part of the shutter plates.
NOTE: Do not run the luminaire with all the shutters closed, as this may cause the luminaire to over-heat.
Interchangeable Lens Trays:
The variable lens tray assemblies are interchangeable so you can change an 18º-34º luminaire to
a 24º-44º. Open the tray, with the tray hanging down, lift up and out to free the hinge.
Cleaning:
Reflector - wipe with a soft cloth to remove accumulated dust.
Lens - the assembly can be removed out of the luminaire, clean with a soft cloth. To remove baked on dust use a window
cleaner.
Accessories:
Suspension Hookclamp (Order Code 20HC)
Adjustable Iris (Order Code 15ACIRIS)
Lens Safety Mesh (Order Code 15ACSM)
24º-44º lens tray (Order Code 15ACLTW)
Rotatable pattern holder (Order Code 15ACGH)
18º-34º lens tray (Order Code 15ACLTS)
Colour Frame
– each luminaire is supplied with a 125mm square colour filter holder. Additional colour frames are available
(Order Code 20CFMF)
Safety and Maintenance:
Philips Selecon has manufactured this luminaire in accordance with recognised best practices to recommended
international safety standards. It is your responsibility to maintain this luminaire in good and safe working condition.
Repairs should only be carried out by suitably qualified persons. Do not operate the luminaire with cracked lens, damaged
cable, etc. Consult your Philips Selecon distributor for assistance. Only replace with damaged parts with authorised Philips
Selecon spares.
N.B.
Luminaire cables
– your Philips Selecon luminaire is fitted with special heat resistant flexible cable, replace with
genuine Philips Selecon spare part cable kit only
– refer to your Philips Selecon distributor. (Replacement cables are
supplied complete with necessary terminal
connectors).
Cable conductor colour codes:
ONLY FIT A PLUG IF YOU ARE A SUITABLY
QUALIFIED TECHNICIAN