Power Requirements
7
PLPROFILE1 MKII LED Luminaires
Installation & User’s Manual
INSTALLATION AND SET UP
1. Power Requirements
WARNING!
The PLPROFILE1 MKII LED Luminaire should be connected to a constant circuit or a relay device. It
should never be connected to a dimmer or circuit controlled by a dimmer.
The PLPROFILE1 MKII LED Luminaire operates on 100 to 240 volts AC (+/- 10%, auto-ranging). The luminaire
contains an auto-ranging power supply. Depending on supply voltage, each luminaire can draw up to 140 Watts. The
maximum through current should not exceed 20 Amps*.
WARNING!
*The Maximum Allowable Input Current of 20 Amps (and the maximum power supply limit of 140
Watts).
Do not overload circuits!
Must be supplied by a branch circuit protected by a maximum 20 Amp circuit
protector. Doit être alimenté par un circuit de dérivation protégé par un maximum de 20 ampères circuit
protecteur. Do not overload circuits!
IMPORTANT AC POWER CONNECTION NOTES:
a. Must be supplied by a branch circuit protected by a maximum 20 Amp circuit protector. Doit être
alimenté par un circuit de dérivation protégé par un maximum de 20 ampères circuit protecteur.
b. When using the daisy-chain connection method, ONLY connect PLPROFILE1 MKII LED Luminaires
to AC Output Connection of PLPROFILE1 MKII LED Luminaires. DO NOT CONNECT OTHER
TYPES OF LUMINAIRES OR DEVICES!
c. Use only approved cable types.
d. Do not overload circuits!
e. Do not connect PLPROFILE1 MKII LED Luminaires to dimmed circuits.
f. The MAXIMUM allowable number of PLPROFILE1 MKII LED Luminaires which can be 'daisy-
chained' on one power feed should not exceed ratings. DO NOT EXCEED!
2. Connecting Power
Units can be powered in one of two ways:
• Direct connection to a AC power source using an AC input cable.
• Daisy chain connection using a interconnect AC cable.
If the unit is supplied with an AC input cable but you did not order an AC input connector,
describes how to connect power to your PLPROFILE1 MKII LED Luminaire. Field wiring of the PLPROFILE1
MKII LED Luminaire is straight forward. A total of 3 wires/conductors need to be brought to the unit. The following
wiring scheme is required: