1.3.   Holding the cabinet

 Warning:

To prevent damage to the LED, do NOT touch the edge of each LED module when holding the cabinet by hand.
Refer to the illustration below for the recommended manner of holding a cabinet.

1.4.  Installation Notes

•  Only use the power cable provided with this product. If an extension cord is required, please consult your service agent. 
•  The product should be installed on a flat surface, or the product may tip over. Leave a space between the rear of the product 

and the wall for proper ventilation. Do not install the product in a kitchen, bathroom or a place exposed to moisture, failure 
to do so may shorten the life of the internal parts. 

•  Do not install the product where it is 5000m and higher in altitude. Failure to do so may result in malfunctions. 

Содержание L Line 31BDL7219L

Страница 1: ...Professional Display Solutions L Line 31BDL7219L User Manual English www philips com welcome ...

Страница 2: ...oning the display make sure the power plug and outlet are easily accessible When turning off the display by detaching the power cord wait 6 seconds before re attaching the power cord for normal operation Ensure the use of an approved power cord provided by Philips at all times If your power cord is missing please contact your local service center Do not subject the display to severe vibration or h...

Страница 3: ...using serious personal injury or death To prevent injury this device must be securely attached to the floor wall in accordance with the installation instructions IEC EN 62368 A product may fall causing serious personal injury or death Many injuries particularly to children can be avoid ed by taking simple precautions such as ALWAYS use cabinets or stands or installation methods recommended by the ...

Страница 4: ...irements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility 2014 30 EU Low voltage Directive 2014 35 EU RoHS directive 2011 65 EU This product has been tested and found to comply with the harmonized standards for Information Technology Equipment these harmonized standards published under Directives of Official Journal of...

Страница 5: ...which should be located near the equipment and easily accessible A protection mark B confirms that the equipment is in compliance with the protection usage requirements of standards PN 93 T 42107 and PN 89 E 06251 Electric Magnetic and Electromagnetic Fields EMF 1 We manufacture and sell many products targeted at consumers which like any electronic apparatus in general have the ability to emit and...

Страница 6: ...UTRAL N BROWN LIVE L GREEN YELLOW EARTH E 1 The GREEN YELLOW wire must be connected to the terminal in the plug which is marked with the letter E or by the Earth symbol or coloured GREEN or GREEN YELLOW 2 The BLUE wire must be connected to the terminal which is marked with the letter N or coloured BLACK 3 The BROWN wire must be connected to the terminal which marked with the letter L or coloured R...

Страница 7: ...有害物质在该部件所有均质材料中的含量均在 GB T 26572规定的限量要求以下 X 表示该有害物质至少在该部件的某一均质材料中的含量超出GB T 26572规定的限量要求 上表中打 X 的部件 应功能需要 部分有害物质含量超出GB T 26572规定的限量要求 但符合欧盟 RoHS法规要求 属于豁免部分 备注 上表仅做为范例 实际标示时应依照各产品的实际部件及所含有害物质进行标示 10 环保使用期限 此标识指期限 十年 电子电气产品中含有的有害物质在正常使用的条件下不会发生外泄或突变 电 子电气产品用户使用该电子电气产品不会对环境造成严重污染或对其人身 财产造成严重损害的期限 废弃电器电子产品回收处理管理条例 提示性说明 为了更好地关爱及保护地球 当用户不再需要此产品或产品寿命终止时 请遵守国家废弃电器电子产品 回收处理相关法律法规 将其交给当地具有国家认可的回收处理资质的厂商进行回收处...

Страница 8: ... Please find out about the local regulations on how to dispose of your old display from your local Philips dealer For customers in Canada and U S A This product may contain lead and or mercury Dispose of in accordance to local state and federal regulations For additional information on recycling contact www eia org Consumer Education Initiative Waste Electrical and Electronic Equipment WEEE Attent...

Страница 9: ...pment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about E waste please visit http www india ...

Страница 10: ...lay cabinet becomes dusty use an air blower which can produce air flow to blow away dust Cautions when cleaning the display Do not use a wet cloth to clean the LED display Do not allow water or other liquid to enter the LED display Do not use tool that generate large amount of static electricity such as a bristle brush The front of the LED display has been specially treated Do not touch the surfac...

Страница 11: ...Installing the modules 13 7 Dehumidification function 15 7 1 Installing the program 15 7 2 Firmware upgrade and verification 15 7 3 Configuring dehumidification settings 20 7 4 Activating Dehumidification function 22 7 5 Cancelling Dehumidification function 22 7 6 Notes 22 8 Using the LED display controller 23 Appendices 24 Appendix A Warranty Statement 24 Appendix B Troubleshooting 26 Appendix C ...

Страница 12: ...contents are complete and in good condition 1 2 Package Contents Please verify that you received the following items with your package content LED display Quick start guide Power cable daisy chain LAN cable RJ45 CAT 5 Quick start guide LED display Power cable daisy chain LAN cable RJ45 CAT 5 Display design and accessories may differ from those illustrated above NOTES For all other regions apply a ...

Страница 13: ...this product If an extension cord is required please consult your service agent The product should be installed on a flat surface or the product may tip over Leave a space between the rear of the product and the wall for proper ventilation Do not install the product in a kitchen bathroom or a place exposed to moisture failure to do so may shorten the life of the internal parts Do not install the p...

Страница 14: ... side Right side 2 4 Top view 2 5 Bottom view No Component No Component Data connector s Power Out connector Power In connector CHECK button The Data connector is an RJ45 connector but it cannot be connected with a network switch or common computer networking device as it is not compatible ...

Страница 15: ... the product can operate normally 3 Check whether each color is displayed normally on the screen from the front side of the display 2 1 To test the cabinet a power cable that connects from the cabinet to the power outlet is required but not provided 3 2 Removing the opening Before breaking the opening determine the number of displays to install and the installation layout to form a large video wal...

Страница 16: ...eep clear space from the mounted displays to the wall Refer to the diagram below for the recommended distance between the LED display and wall Installing the product in poorly ventilated spaces may damage the LED A wall mount kit in some regions sold separately or available from third party vendors allows you to mount the LED display on the wall For detailed information on installing the wall moun...

Страница 17: ...le inner hexagon wrench size 7 Optional accessory CTN BM907005 Not included Optional accessory CTN BM907000 Ensure that the Philips wordmark on the connecting plate is facing the cabinet Step 2 Move up to install the next row Install the connecting plates on the bracket Rotate the hex key clockwise until the screw bolts are inserted Do not tighten the screw bolts yet as this will cause unevenness ...

Страница 18: ...are inserted Do not over tighten the screw bolts yet as you may need to adjust the connecting plates again Step 4 Tighten the screw bolts 1 Move up to install the next row Install the connecting plates on the bracket Rotate the hex key clockwise until the screw bolts are inserted 2 Do not tighten the screw bolts yet as this will cause unevenness of the connecting plates 2 1 ...

Страница 19: ...t seems to be tilting to one side adjust it until the display becomes level Step 6 Align the second cabinet with the connecting plate and secure the cabinet to the holes on the connecting plate Rotate the hex key clockwise until the screw bolts are inserted Do not over tighten the screw bolts yet as you may need to adjust the connecting plates again ...

Страница 20: ...two cabinets must be considered Follow the installation steps below Tighten the screw bolts 1 Repeat the above steps until all cabinets are mounted onto the bracket Use the feeler gauges to ensure accurate gap is reserved between the cascaded cabinets Insert 2 pieces of 0 5mm feeler gauge into the gap between two parts as illustrated below 2 The feeler gauges are not provided with the product Adju...

Страница 21: ...onditions 1 Calibration should be ON 2 Ambient temperature should not exceed 45 degrees Celsius If the ambient temperature between glass window and LED display exceeds 45 degrees Celsius then active cooling is required or more distance from glass window is required for more airflow to cool down temperature below 45 degrees Celsius This guideline will work for most shopping malls and indoor usage w...

Страница 22: ...binet to the Power In port of the second cabinet 2 Connect the signal cable from the Data port of the first cabinet to Data port of the second cabinet for video signal transmission Connect the power cable from the Power In port of the first cabinet to the power outlet 3 Connect one end of the data cable of the first cabinet to the LED display controller 4 Repeating steps 2 3 enables the daisy chai...

Страница 23: ... displays to install then identify the alignment pins on the top of the cabinets As the position of the alignment pin differs by models you may need to adjust the alignment pin if necessary To make such adjustment use a hexagon wrench not provided to remove the alignment pin and insert it into the new alignment screw thread hole Notes The tool used in this step is Inner hexagon wrench size 4 ...

Страница 24: ...el that is affixed to the interior of the cabinet Whereas one label can be found inside each module indicating the serial number of the module This label provides important information to uniquely identify every single module as it allows you to easily locate the correct module that connects to the cabinet When installing the module onto the cabinet make sure the serial number on the module label ...

Страница 25: ...d of the flat cable is already attached to the hub board use the other end to connect it to the module Before connection make sure that the arrow sign on the module is pointing up Connect the flat cable to the connector on the module until it clicks into place To prevent reversed connection when connecting the cable locate the star sign on the module first Ensure that the star sign and the red str...

Страница 26: ...s Likewise the heat generated in the fade up process can take moisture out of the LED display A stepwise fade up process can avoid impulse current caused by damp diode when booting up the display 7 1 Installing the program Dehumidification function is a custom built procedure designed for use with specific LED display controller firmware 1 Get the program NovaLCT V5 3 1 Plus from your local distri...

Страница 27: ...admin or 666888 in the main menu See Figure 1 3 Figure 1 3 4 A dialog box will then appear as shown in Figure 1 4 Select the Communication port for operation Click Reconnect if you need to reconnect the LED display controller Figure 1 4 ...

Страница 28: ...of the LED display controller you are using a corresponding firmware will then be provided to you Click Browse to search the firmware file provided by your supplier See Figure 1 5 Figure 1 5 6 Click Update to start updating See Figure 1 6 Figure 1 6 ...

Страница 29: ...31BDL7219L 18 7 After the update is complete click OK See Figure 1 7 Figure 1 7 ...

Страница 30: ...efresh default value is Refresh All Verification process starts by checking the version numbers between the LED display controller and the one with dehumidification If the version numbers are consistent it indicates that firmware upgrade is successful See Figure 1 8 Figure 1 8 ...

Страница 31: ...ly over a period of time follow the steps below before you turn the display off 1 Run the program NovaLCT V5 3 1 Plus 2 After screen configuration is complete click Brightness See Figure 2 1 Figure 2 1 3 In brightness adjustment screen click the Enable Dry mode checkbox See Figure 2 2 Figure 2 2 ...

Страница 32: ...ted dehumidification duration Figure 2 3 5 Click Send and Save to HW then check that brightness is set successfully in the information box at the bottom of the screen Figure 2 4 6 To make sure the dehumidification function is initiated wait 1 minute before you exit the brightness setting menu ...

Страница 33: ...ith corresponding program please contact us for support 2 The maximum value you can set for dehumidification duration is 240 minutes while the minimum value allowed is 5 minutes 3 The principles of duration and brightness enhancement 4 Based on the duration set by user it will be divided into 15 proportional levels automatically The display brightness will also be divided into 15 levels ranging fr...

Страница 34: ...n configuration Visit Novastar website to learn more about Novastar s LED display controller and select the one that suit your needs according to the resolution and screen configuration of your display https www novastar tech products To download the Novastar software and user s guide click on the following link https www novastar tech downloads controller ...

Страница 35: ...ase of the product Please note that all parts including repaired and replaced parts are covered only for the duration of the original warranty period WHAT IS EXCLUDED Your warranty does not cover Consequential damages including but not limited to loss of data or loss of income nor compensation for activities done by yourself such as regular maintenance installing firmware updates or saving or rest...

Страница 36: ...nt Standard warranty period for PHILIPS signage display is listed as below for areas not covered in this table please follow the local warranty statement Region Warranty Period USA Canada 2 years China 1 year Asia Pacific 2 years Europe 2 years Brazil 2 years Note that for professional products the specific warranty terms of the sale or purchase agreement may apply ...

Страница 37: ...The main switch on the power distribution box is off Make sure the power distribution box is switched on The LED display controller is off Inspect whether the power connection is correct and the switch has been turned on Inspect whether the LED display controller output has signal and shows blank screen Check whether the mode and parameter of screen configuration are correct Check whether there is...

Страница 38: ... 0 0 0 0 0 Relative Humidity 10 20 30 40 50 60 70 80 Dew point C 28 08 20 33 15 54 12 01 9 19 6 84 4 82 3 03 Celsius C 10 10 10 10 10 10 10 10 Relative Humidity 10 20 30 40 50 60 70 80 Dew point C 20 29 11 96 6 80 2 99 0 04 2 58 4 77 6 70 Celsius C 25 25 25 25 25 25 25 25 Relative Humidity 10 20 30 40 50 60 70 80 Dew point C 8 75 0 47 6 22 10 46 13 85 16 69 19 14 21 30 Celsius C 35 35 35 35 35 35 ...

Страница 39: ...110084 00 LED module flatcable 45cm 20x BZ110083 00 LED module flatcable 25cm 20x BM107000 00 Service Tool kit 7 8 9000 Charger 3Ah 1x BM107001 00 Front Tool Battery 7 8 9000 3Ah 1x BM199006 00 Value toolbox TBD 1x BM199005 00 Toolbox 7 8 9K M10 3xT Hex SD ASGL USB32 BZ207000 00 PSU 7000 series 200W 2x BZ307000 00 HUB board 7000 series 5x CRD20086 00 Novastar Rec card A5S 7xxx 5x CRD20089 00 Novas...

Страница 40: ...HK CRD20002 75 Controller Novastar MCTRL600 CN AUS CRD20002 67 Controller Novastar MCTRL600 THAI CRD20003 00 Controller Novastar MCTRL660 EU CRD20003 17 Controller Novastar MCTRL660 US CRD20003 05 Controller Novastar MCTRL660 HK CRD20003 75 Controller Novastar MCTRL660 CN AUS CRD20003 67 Controller Novastar MCTRL660 THAI CRD20004 00 Controller Novastar MCTRL660PRO EU CRD20004 17 Controller Novasta...

Страница 41: ...ontroller Novastar TB3 HK CRD20009 75 Controller Novastar TB3 CN AUS CRD20009 67 Controller Novastar TB3 THAI CRD20010 00 Controller Novastar TB6 EU CRD20010 17 Controller Novastar TB6 US CRD20010 05 Controller Novastar TB6 HK CRD20010 75 Controller Novastar TB6 CN AUS CRD20010 67 Controller Novastar TB6 THAI CRD20011 00 Controller Novastar TB8 EU CRD20011 17 Controller Novastar TB8 US CRD20011 05...

Страница 42: ...rate Hz 2100 3900 14 bits 3900Hz Frame Frequency Hz 50 60 According to IDMS standard Power Max power consumption before calibration W 115 Max power consumption after calibration W 95 Cabinet Typical Power consumption W 32 Cabinet black screen consumption W 10 BTU M2 BC 2098 BTU M2 AC 1728 Input Voltage AC100 240V 50 60Hz Operating conditions Operation Temperature 20 C 45 C Storage Temperature 20 C...

Страница 43: ...nnector 3 core socket C14 in C13 out Cabinet Construction Die Casting Aluminum 90 Module LED Type SMD 1515 Copper wire Pixel constitution 1R1G1B LED Lifetime Hrs 50 000 Pixel Pitch mm 1 9 Module Size WxH in mm 249 9 x 249 9 tolerance 0 05 0 1 Module Resolution W H in pixels 128 x 128 Conformal coating UV resistant Yes LED Module Bottom side and HUB board Accessories Power cable short 650 mm Power ...

Страница 44: ...ious temperatures is as follows Temperature 20o C 60o C 80o C 120o C The tension value of each magnet Kg 0 78 0 78 0 78 0 25 Tension value per module Kg 7 7 7 2 25 2 The maximum weight of each module is 0 5kg According to UL2442 standard 4 times the safety factor is 2 0kg It can be seen from the above table that when the temperature is 120 degrees Celsius the residual pull value of the magnet is c...

Страница 45: ...31BDL7219L 34 Appendix G Power Data cable measure Installation power cable measure ...

Страница 46: ...35 1 Meter Ending Installation 1 5 Meter Ending Installation 2 Meter Ending Installation 22BDL7219L 31BDL7219L 41BDL7219L Power cable 250mm Power cable 600mm Power cable 600mm Power cable 1000mm Power cable 1000mm ...

Страница 47: ...31BDL7219L 36 Installation data cable measure ...

Страница 48: ...ing Installation 1 5 Meter Ending Installation 2 Meter Ending Installation 22BDL7219L 31BDL7219L 41BDL7219L LAN cable RJ45 CAT 5 1100mm H and V LAN cable RJ45 CAT 5 1100mm LAN cable RJ45 CAT 5 1100mm LAN cable RJ45 CAT 5 1500mm ...

Страница 49: ...nt screw thread hole Alignment hole Opening for cable 1 L 4 3 2 Installation R 4 3 2 Installation L 4 2 3 Installation R 4 2 3 Installation 1 2 3 5 6 7 4 2 3 5 6 4 1 2 1 2 1 2 3 5 6 4 8 1 2 3 5 6 7 4 8 1 3 2 4 1 3 2 4 1 3 2 4 move 1 alignment pin move 1 alignment pin move 1 alignment pin move 1 alignment pin move 1 alignment pin move 3 alignment pins ...

Страница 50: ...1 Meter Ending Installation 2 Meter Ending Installation add 1 alignment pin add 1 alignment pin add 3 alignment pins move 2 alignment pins add 2 alignment pins move 2 alignment pins add 2 alignment pins move 3 alignment pins move 2 alignment pins ...

Страница 51: ...esponsibility of Top Victory Investments Ltd and Top Victory Investments Ltd is the warrantor in relation to this product Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N V and are used under license Specifications are subject to change without notice Version V1 00 2022 01 21 ...