background image

MATERIAL SAFETY DATA SHEET

PRODUCT: L 1250 - HPM, L 1261 - HPA

 

(325779, 305581)

Revised: 6/01

SECTION 1:  MANUFACTURER

Manufacturer's Name and Address:

Philips Lighting Company

                                                             A Division of Philips Electronics

North America Corporation
200 Franklin Square Drive
Somerset, NJ  08875

Emergency Telephone No.: (800) 424-9300 CHEMTREC

(732) 563-3197 Environmental

Other Information Calls:

(800) PLC-BULB

                                         

SECTION 2:  HAZARDOUS INGREDIENTS

OSHA (PEL)      ACGIH (TLV)      

%

Mercury (7439-97-6)

.1mg/m

3

Ceiling              .025mg/m

3

8hr.TWA      

<.02

Lead Iodide (10101-63-0) *

.05mg/m

3

          < .1mg/m_             

<.02

 Gallium Iodide (13450-91-4)*        

NONE ESTABLISHED     

<.02

Cobalt (7440-48-4)+

  .1 mg/m_ 

NONE  EST'D     

<.02

Krypton - 85

HPM less than 15 nCi;      HPA less than 50 nCi.

*HPM Only.

+HPA Only.

                        

                                        

A division of

Philips Electronics North America Corporation

200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
Tel: 732.563.3000

L 1250 - HPM, L 1261 - HPA

Содержание L 1250 - HPM

Страница 1: ...63 3197 Environmental Other Information Calls 800 PLC BULB SECTION 2 HAZARDOUS INGREDIENTS OSHA PEL ACGIH TLV Mercury 7439 97 6 1mg m3 Ceiling 025mg m3 8hr TWA 02 Lead Iodide 10101 63 0 05mg m3 1mg m_ 02 Gallium Iodide 13450 91 4 NONE ESTABLISHED 02 Cobalt 7440 48 4 1 mg m_ NONE EST D 02 Krypton 85 HPM less than 15 nCi HPA less than 50 nCi HPM Only HPA Only A division of Philips Electronics North ...

Страница 2: ... AND OR SURROUNDING ENVIRONMENT COULD OCCUR THEREBY CREATING A RISK OF PERSONAL INJURY PROPERTY DAMAGE OR FIRE SECTION 5 REACTIVITY DATA Stability Envelope is stable Incompatibility Envelope can be affected by oils and fats deposited on surface from fingers Handling of envelope should only be done with gloves While the amount of lead iodide is small and exposure occurs only if the lamp is broken t...

Страница 3: ... contains a small amount of mercury together with a small amount of lead iodide Under the toxicity characteristic leaching procedure TCLP promulgated by the United States E P A tests of used or spent high intensity discharge lamps indicate that these lamps generally are considered to be hazardous when discarded Fed Reg 7 27 94 EPA has issued the Universal waste Rule for lamps which fail the TCLP F...

Страница 4: ...ing lamp to operate until it fails is not recommended and may increase the risk of inner arc tube rupture 5 Use within voltage limits recommended by ballast manufacturer Do not operate lamp at higher than specified power 6 The permissible maximum operating temperatures e g the pinch temperatures the tempera ture of the bulb wall as indicated on the product leaflet may not be exceeded 7 Lamp should...

Страница 5: ...ire D008 RCRA classification If state adopts universal waste rule spent lamps can be shipped using common carrier and bills of lading Contact your state environmental agency for guidance Prepared 8 9 95 S21 95001 A division of Philips Electronics North America Corporation 200 Franklin Square Drive P O Box 6800 Somerset NJ 08875 6800 Tel 732 563 3000 ...