background image

Service Manual

Philips Domestic Appliances and Personal Care

Published by Philips Domestic Appliances and Personal Care 

Printed in the Netherlands 

© Copyright reserved 

Subject to modification

  

Shaver

HQ7100

07/03

PRODUCT INFORMATION

General:

- Mains operation
-  World-wide automatic voltage selection
-  Electronic on/off switch
- Washable

Safety information

-  This product meets the requirements regarding 

interference suppression on radio and TV.

-  After the product has been repaired, it should function 

properly and has to meet the safety requirements as 
officially laid down at this moment.

TECHNICAL INFORMATION

-  Voltage 

:  100 - 240 Volt / 50 - 60 Hz 

- Motor voltage 

: 15 Volt

-  Shaving heads 

:  HQ8 - 4222 036 05820

- SAP coding 

: HQ7100

DISASSEMBLY- AND  RE-ASSEMBLY ADVICE

Disassembly:

-  Remove shaving unit, to prevent damaging during 

repairing.

-  Remove the 2 screws (

A

) out of the hairchamber.

-  Remove the hairchamber from the body.
-  Remove the 2 screws (

B

) on the backside of the shaver.

-  Remove the cover.
-  Remove the side grips.
-  Remove the housing by bending the hooks with a 

screwdriver.

-  Take out the basic body.

REPAIR INSTRUCTION

-  No specific issues

OPTIONAL (accessories)

- Pouch : 4222 036 14160