background image

PARTS LIST + DISASSEMBLY ADVICE STAND

SAFETY CAP 21

COMPLETE TRAY  22

Note:  pressure fi xation rubber 

through the tray.

SUPERIOR STAND 

PRINTED 29

Remove 

screws A  (4x)

Remove the SUPERIOR STAND 
and you will see the respective 
parts of the Boiler.

ADJUSTMENT AND  CONTROLS

–  To avoid leakage of the sealings and damage to the 

components in and on the boiler, NEVER clean the boiler 
with vinegar, a descaling agent or other chemicals.

–  The boiler doesn’t contain serviceable parts.

Never disassemble the boiler body or components and/or 
components on and in the boiler.

–  The boiler is required to be rinsed after every ten times use.

–  ALWAYS REPLACE BOILER (Pos 26)  WHEN:

*

  the mechanical safety valve has been activated.

*

  the boiler thermostat or hand –resettable safety 

thermostat are open.

*

  the electrovalve fails or the sieve is soiled with scale.

–  After the product has been repaired, it should function 

properly and has to meet the safety requirements as laid 
down and offi cially established at this moment.

 Pos

Description

Service code

21

22

23

24

25a

Safety cap

Complete tray

Tray rubber foot

Boiler rubber foot

Intermediate supply cable (Europe)

9965 000 13247

9965 000 13248

9965 000 13249

4822 462 71999

9965 000 01793

25b

26

27

28

29

Intermediate supply cable (Italy)

Inox boiler unit

Electrovalve

Main switch

Superior stand printed GC 6022

9965 000 01792

9965 000 13250

4822 218 11561

9965 000 13251

9965 000 13257

30

31

32

Inferior stand

Tray stopper prevent Iron from sliding

Filling hole gasket

9965 000 13258

9965 000 13254

9965 000 01782

Содержание GC 6022

Страница 1: ...e 4322 277 00840 02 03 TECHNICAL INFORMATION Voltage 220 240V Frequency 50 60 Hz Power consumption Iron 800 W Boiler 1200 W Pressure 2 5 bar Water advice Suitable for tap water use However if the tap water in your area is very hard we advise you to mix it with a equal portion of distilled water or to use distilled water only Soleplate Careeza is a multi layer chemical substance that gives an excel...

Страница 2: ...EXPLODED VIEW IRON 3 6 10 11 5 4 1 12 9 2 B1 8 7 B2 A B3 C1 C2 C3 ...

Страница 3: ...65 000 01888 6 7 8 9 10 Iron Handle Intermediate cable microswitch Swivel Thermostat bush Iron skirt 9965 000 13236 9965 000 13237 9965 000 13238 9965 000 01682 9965 000 13245 11 12 Soleplate unit Electrovalve trigger 9965 000 13246 9965 000 13255 Cut out Boiler thermostat Main switch STAND IRON Steam switch Thermostat Electro valve Boiler heating element p F N ...

Страница 4: ... 1 remove screw A remove connection remove hose disassemble BACKPLATE 2 disassemble INLAY 3 IRON LAMP 4 MICRO SWITCH 5 remove screw B 3x disassemble IRON HANDLE 6 REPLACE IRON SKIRT 10 SOLEPLATE UNIT 11 disassemble DIAL 1 remove screw A remove connection remove hose disassemble BACKPLATE 2 disassemble INLAY 3 IRON LAMP 4 MICRO SWITCH 5 remove screw B 3x disassemble IRON HANDLE 6 disassemble INTERM...

Страница 5: ...EXPLODED VIEW STAND 29 24 27 28 22 31 21 32 23 25a 25b 26 30 A A A ...

Страница 6: ...cal safety valve has been activated the boiler thermostat or hand resettable safety thermostat are open the electrovalve fails or the sieve is soiled with scale After the product has been repaired it should function properly and has to meet the safety requirements as laid down and officially established at this moment Pos Description Service code 21 22 23 24 25a Safety cap Complete tray Tray rubbe...

Отзывы: