Philips Domestic Appliances and Personal Care
Published by Philips Domestic Appliances and Personal Care
Printed in the Netherlands
© Copyright reserved
Subject to modification
Specialist
Vacuum
cleaner
FC 9104
/A
/B
PRODUCT INFORMATION
- Colour
/A
:
Mint
green
Version
/B
:
2000
W
logo
- Maximum air displacement
: 37 l/sec.
- Maximum vacuum water column
: 310 cm
- Power consumption (IEC) 230 V
: 1500 W
- Duststorage capacity
: 3 L
- Type number dustbag
: FC 8021
- Cord length (depends on version) : 7 metres
- Filter system
: Paper dustbag
: Exhaust HEPA air fi lter
: Motor inlet fi lter
- Dimensions of cleaner
: 460 x 315 x 270 mm
- Dimensions of packaging
: 595 x 395 x 295 mm
- Net weight
: 5.88 kg
- Gross weight
: 9.135 kg
OPTIONAL
- FC 8021
S-bags
- FC 8030
AFS-fi lter
- FC 8031
HEPA Air Filter
- FC 8034
Upgrate kit Active Carbon Filter
- HR 6988
Turbo brush nozzle
- HR 8040
Polishing nozzle
SERVICE INFORMATION
- Open the appliance, fi rst remove the exhaust fi lter grille
(
item 20
), and then remove the 2 screws -
C
of the switch
control panel (
item 15
).
- Undo and remove the 9 screws -
C
in the upper housing
(
item 8
). You will require a screwdriver with a 14.5 cm-long
shank for this.
4322 277 00576
02/05
Depending on the version screwdriver 9965 000 08332 for cross
head or onwards 0234 screwdriver 4322 009 08490 for T15 can be
used.
-
Item8
Spare part is standard
supplied without a hole, you must drill
a hole 2mm dia, so the air can reach
the sensor on the PCB via the
pressure tube.
-
Item 22
Replace the HEPA fi lter as
soon as the pilot light of the fi lterfull
indicator goes on.
- The component confi guration shown in the exploded view may
differ in case of specifi c versions. The components are
distinguished by means of code numbers.
- When the repair is fi nished, check whether all functions of the
appliance work properly.
-
Item 4
, cotton dustbag, is used in countries in which paper
dustbags are not available.
- To disassemble the cord winder, use TORX screwdriver no.T15,
which is one of a set consisting of T20; T15; T10; T9; T8; T7 and T6
(code number 4822 395 50145).
- If the reel half spring unit is replaced, shaft
A
must be lubricated
with
silicone grease
. Do not apply any silicone grease to or spill
any grease on terminals (
43
) or conductors (
42
).
-
Item 40
is provided with a long cord-winder spring, but both long
and short cords can be used in combination with this spring.
(L = 9.3 m)
- Depending on the original cord, the spare cord must be shortened
to the length of the original cord.
- The cord winder spring must be tensioned to the maximum level
and then be rewound approx. 1.5 turn
-
Item 13
, air valve, opens to cool the motor if the air displacement
is too low or if the airfl ow is blocked.
- To adjust the telescopic tube (
item 59
) to the required length, push
the adjustment collar in the direction of the arrow while sliding the
top section of the telescopic tube into or out of the lower section.
- If the function of the electronic control unit (
item 12
) is not
required, the Triac must be short-circuited in the manner shown in
the circuit diagram.
- When the vacuum cleaner is used to suck up fi ne dust the pores of
the dustbag may become clogged, causing the passage of air
through the dustbag to become obstructed. As a result, the
dustbag-full indicator will indicate that the dustbag needs to be
replaced, eventhough the dustbag is not full at all.
C
2x
C
9x
Ø 2mm