Страница 1: ...Efficia Rack Release A 01 Revision B English Installation and Configuration Guide ...

Страница 2: ...Part Number 453564626901 Revision B First Edition ...

Страница 3: ...Efficia Rack INSTALLATION AND CONFIGURATION GUIDE Release A 01 Revision B English ...

Страница 4: ...amboré Barueri SP Brasil 06460 030 Warranty Disclaimer The information contained in this document is subject to change without notice Philips Medical Systems makes no warranty of any kind with regard to this material including but not limited to the implied warranties or merchantability and fitness for a particular purpose Philips Medical Systems shall not be liable for errors contained herein or ...

Страница 5: ...ld User interface text Open the System Menu Italic Variables document titles product name encryption configuration software version cfg Manual de Operação do Rack Efficia Decimal Points Because the Efficia CM Series monitor uses a period to indicate a decimal point in decimal numbers for example 10 0 all decimal numbers in this guide use a period as a decimal point Commas are not used as decimal p...

Страница 6: ...figured options Packaging Symbols The following symbols appear on the rack s packaging Symbol Description Symbol Description Keep upright Keep dry Fragile handle with care Temperature limitation Stacking limit by number Humidity limitation Atmospheric pressure limitation Input Output Connector Port Symbols The following symbols appear next to the input output ports on the rear panel of the rack Sy...

Страница 7: ...evice may not contain all of these symbols Symbol Description Symbol Description Manufacturer s name and address Date of manufacture Serial number Part number Model number Unique Device Identification code barcode Caution consult accompanying documents Ingress protection against vertically falling water drops Compliance with WEEE standard INMETRO mark Made in Manaus mark ...

Страница 8: ...Customer Care Solutions Center or your local Philips representative Warning If multiple instruments are interconnected or if multiple instruments are connected to a patient the sum of the leakage currents may exceed the limits given in ABNT NBR IEC 60601 1 system requirements Electromagnetic interference may cause disruption of performance Protect the monitor and the rack from sources of intense e...

Страница 9: ...k 2 1 Part Numbers 2 2 Installing the Optional Bottom Support with the Universal Clamp 2 3 Installing the Optional Support Plate with the Universal Clamp 2 5 Installing the Optional Support Plate with the Arm Mount 2 7 Connecting the Rack to the Monitor 2 8 Powering Up 2 10 Connecting the Plug in Modules to the Rack 2 11 3 Returning the Rack 3 1 Submitting a Damage Claim 3 1 Returning the Rack For...

Страница 10: ......

Страница 11: ...version B XX or newer Efficia Rack Intended Audience This guide is for biomedical engineers or technicians responsible for installing and configuring Philips patient monitoring systems For detailed information about the installation of the Efficia CM Series patient monitors see the Efficia CM Series Patient Monitors Installation and Configuration Guide Navigation Controls You can access the functi...

Страница 12: ...r Care Center The following documents are available on Philips InCenter Efficia Rack Installation and Configuration Guide Provides instructions for unpacking installing and connecting all hardware Also includes instructions for returning the rack Efficia Rack Service Guide Provides information about maintaining basic troubleshooting and basic performance verification testing of the rack Efficia Ra...

Страница 13: ...broken components dents or scratches on the surface of the equipment 3 Store all documentation in an appropriate location 4 Save the packaging material for possible reuse Verify that you have received all of the following components The Efficia Rack Also contained in the package A PoweredUSB cable The Efficia Rack documentation The Manual de Operação do Rack Efficia If you purchased any of the fol...

Страница 14: ...not supplied by Philips are not approved or supported for use with the Efficia CM Series monitors and the Efficia Rack Properly secure the rack when in use to avoid injury to patient and staff Part Numbers Description Part Number Bottom Support with Universal Clamp 989803198321 Support Plate for Accessories 989803198311 Arm Mount 989803195571 Rail for Wall Mount 989803152951 ...

Страница 15: ...e optional bottom support with the universal clamp Step 1 First you need to assemble the support accessory into the bottom support Position the support accessory over the center of the bottom support Use the washer together with each of the M4x10 Torx screws on the Universal Clamp side to tighten the screws Note The universal clamp can be mounted both horizontally and vertically in relation to the...

Страница 16: ...ion the bottom support on the bottom of the rack and use a Phillips driver to tighten the screws 3 Ensure that all the screws are securely tightened and there is no looseness in the assembly Caution If you connect the Dixtal Gases module ensure that the rack is positioned in a way that watertrap can be used in the vertical position Otherwise the efficacy of the filter of the watertrap cannot be gu...

Страница 17: ...erve as an interface for the connection of the support accessories To install the optional support plate with the universal clamp Step 1 First you need to assemble the universal clamp onto the support plate using the two M4x10 Torx screws and two washers that come with the universal clamp Note The universal clamp can be mounted both horizontally and vertically in relation to the support plate Note...

Страница 18: ... use a Phillips driver to tighten the four screws 3 Ensure that all the screws are securely tightened and there is no looseness in the assembly Caution If you connect the Dixtal Gases module ensure that the rack is positioned in a way that watertrap can be used in the vertical position Otherwise the efficacy of the filter of the watertrap cannot be guaranteed Note The maximum aperture of the Unive...

Страница 19: ...e Optional Support Plate with the Arm Mount To install the optional support plate with the arm mount Step 1 First you need to assemble the support accessory into the support plate Tighten the screws that come with the support accessory into the center of the support plate Note Ensure to follow any additional instructions that comes with the support accessory ...

Страница 20: ...n that comes with the rail for wall mount 4 Then you need to assemble the arm mount in the rail Follow the instruction that comes with the rail for wall mount and arm mount 5 Ensure that all the screws are securely tightened and there is no looseness in the assembly Connecting the Rack to the Monitor Caution Do not allow liquid to enter the connectors Wet connectors could prevent connected devices...

Страница 21: ...onnect the rack Step 1 Connect one of the ends of the PoweredUSB cable into the PoweredUSB connector located on the rear panel of the rack 2 Connect the other end of the PoweredUSB cable into the PoweredUSB connector located on the rear panel of the monitor 3 Ensure that cable is safely attached to both the rack and the monitor ...

Страница 22: ... powered up by the monitor through the PoweredUSB cable This means that whenever the monitor is powered up the rack is also powered up You can power up the rack in two ways By connecting the rack to a previously powered up monitor By connecting the rack to a powered down monitor and then performing the monitor power up sequence Note For more information about powering up the monitor see the Effici...

Страница 23: ...s securely locked the plug in module 3 The image of the plug in module appears on the Measurements menu when the plug in is correctly connected to rack 4 To disconnect the plug in module press the ejection button corresponding to slot that the plug in is connected Warning Ensure that the plug in modules are securely attached to the rack to avoid injury to patient and staff Caution If you connect t...

Страница 24: ......

Страница 25: ...d any shipping documents with the RMA number Warning Before returning any equipment to Philips Back up the configuration For more information see Exporting Configuration Settings on the Efficia CM Series Patient Monitors Installation and Configuration Guide Clean and disinfect it For detailed information see the Instructions for Use supplied with your rack To pack the rack for return disconnect al...

Страница 26: ...id contaminating or infecting personnel the environment or other equipment disinfect and decontaminate the rack before disposing of it in accordance with your country s laws For more information see the resources listed below Philips Healthcare gives support for Recovery of reusable parts The recycling of useful materials by competent disposal companies Safe and effective disposal of equipment For...

Страница 27: ...d on to a new user the previous user may still receive important safety related information such as bulletins and field change orders In many jurisdictions there is a clear duty on the previous user to communicate such safety related information to new users Previous users who are not able or prepared to do this should inform the Philips Customer Care Solutions Center about the new user so that Ph...