4-1
Spindle motor does not move
Yes
No
No
Yes
Check whether “M5V”
(+5V) voltage is normal.
Correct connection
Check the M5V power supply
Check/ Replace U1
Check/Replace the loader,or the bad part.
Yes
No
Go
Check the FFC connection
between 24PIN and the loader.
1.Whether the R12 is eroded or
badly soldered.
2.Whether peripheral components
between U1 and xp5 are eroded or
badly soldered.
Trouble shooting chart
Motor no move